Continuous Subcutaneous Glucose Monitoring Improved Metabolic Control in Pediatric Patients With Type 1 Diabetes: A Controlled Crossover Study
- 1 May 2003
- journal article
- clinical trial
- Published by American Academy of Pediatrics (AAP) in Pediatrics
- Vol. 111 (5) , 933-938
- https://doi.org/10.1542/peds.111.5.933
Abstract
Objective. To improve metabolic control and prevent complications, both acute and late, we need to adjust treatment on the basis of the blood glucose (BG) profile, as not even the most active BG self-monitoring gives sufficient information. Design. We have used Continuous Glucose Monitoring System (CGMS; Medtronic MiniMed, Northridge, CA) in a controlled crossover study including 27 diabetic patients aged 12.5 ± 3.3 (mean; standard deviation; range: 5–19) years. All patients were treated with intensive insulin therapy, 14 with multiple injections, and 13 with pumps. The patients were randomized into an open or blind study arm. Both arms wore the CGMS sensor for 3 days every 2 weeks. CGMS profiles were used in the open study arm to adjust insulin therapy at follow-up visits every 6 weeks. Both the patients and the diabetes team were masked to the CGMS profiles in the blinded arm, and insulin therapy adjustments were based solely on 7-point BG profiles performed by the patients. At 3 months the 2 study arms were crossed over. Results. Despite initial problems with a device new to both patients and the diabetes team, hemoglobin A1C decreased significantly in the open arm (from 7.70%–7.31%) but not in the blind arm (7.75%–7.65%). A total of 26/27 patients experienced daytime low subcutaneous glucose (Conclusions. Use of CGMS facilitated an improved treatment, and patients received new insight and increased motivation. In this study, we found CGMS to be a useful tool for education and improving metabolic control.Keywords
This publication has 12 references indexed in Scilit:
- A Pilot Study of the Continuous Glucose Monitoring SystemDiabetes Care, 2001
- Limitations of Conventional Methods of Self-Monitoring of Blood GlucoseDiabetes Care, 2001
- Persistent Differences Among Centers Over 3 Years in Glycemic Control and Hypoglycemia in a Study of 3,805 Children and Adolescents With Type 1 Diabetes From the Hvidøre Study GroupDiabetes Care, 2001
- Continuous Subcutaneous Glucose Monitoring in Children With Type 1 DiabetesPediatrics, 2001
- Continuous glucose monitoring used to adjust diabetes therapy improves glycosylated hemoglobin: a pilot studyDiabetes Research and Clinical Practice, 1999
- Insulin management and metabolic control of Type 1 diabetes mellitus in childhood and adolescence in 18 countriesDiabetic Medicine, 1998
- Hypoglycaemia During Intensified Insulin Therapy of Children and AdolescentsJournal of Pediatric Endocrinology and Metabolism, 1998
- Comparisons of Studies on Diabetic Complications Hampered by Differences in GHb MeasurementsDiabetes Care, 1996
- Effect of intensive diabetes treatment on the development and progression of long-term complications in adolescents with insulin-dependent diabetes mellitus: Diabetes Control and Complications TrialThe Journal of Pediatrics, 1994
- Declining Incidence of Nephropathy in Insulin-Dependent Diabetes MellitusNew England Journal of Medicine, 1994