The Effect of Exercise on the Atrial Electrogram Voltage in Young Patients
- 1 December 1991
- journal article
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 14 (12) , 2092-2097
- https://doi.org/10.1111/j.1540-8159.1991.tb06479.x
Abstract
Atrial electrogram sensing is an important function in active individuals with permanently implanted bipolar dual chamber pacing systems. We undertook to determine the effect of vigorous exercise on the atrial electrogram size in 11 children and young adults (average age 12 years). Using a telemetry signal through a handheld programming wand, nine tracings were completely and clearly recorded for analysis. Six patients had tined/passive fixation atrial leads and three patients had screw-in/active fixation lead systems. All leads were bipolar. The atrial electrogram size for each patient was measured at rest and at each minute of exercise. The atrial electrogram size decreased with exercise from a mean of 5.08 mV to 3.44 mV (range 0.9-4.25 mV) (P = 0.002). The 1.64 mV mean decrease represented a 33.8% reduction (range 19%-56%) (P less than 0.001). There was no difference in the change in atrial electrogram size between the two lead types. Treadmill exercise testing with telemetric data of atrial electrograms showed a decrease in atrial electrogram size produced by exercise and may be helpful in determining appropriate atrial sensitivity settings in selected individuals. Because of the documented decrease in atrial electrogram size produced by exercise, we recommend obtaining maximal atrial electrograms at the time of implant and use of pacing systems that allow maximal flexibility in atrial sensing especially in athletically active individuals.Keywords
This publication has 9 references indexed in Scilit:
- Stability of Pacing Threshold, Impedance, and R Wave Amplitude at Rest and During ExercisePacing and Clinical Electrophysiology, 1990
- Physical Determinants of the Endocardial P WavePacing and Clinical Electrophysiology, 1990
- Effect of rate augmentation and isoproterenol on the amplitude of atrial and ventricular electrogramsThe American Journal of Cardiology, 1990
- Atrial signal variations and pacemaker malsensing during exercise: A study in the time and frequency domainJournal of the American College of Cardiology, 1988
- Decrease in Canine Endocardial and Epicardial Electrogram Voltages with Exercise: Implications for Pacemaker SensingPacing and Clinical Electrophysiology, 1988
- Atrial Sensing Performance of AV Universal Pacemakers During ExercisePacing and Clinical Electrophysiology, 1988
- Valsalva-Induced Variations in the Intracardiac SignalPacing and Clinical Electrophysiology, 1985
- The Use of Exercise Testing in Children to Evaluate Abnormalities of Pacemaker Function not Apparent at RestPacing and Clinical Electrophysiology, 1985
- Cardiac pacing and pacemakers III. Sensing the cardiac electrogramAmerican Heart Journal, 1977