Evaluation of the new Viewmax laryngoscope in a simulated difficult airway
- 25 April 2006
- journal article
- research article
- Published by Wiley in Acta Anaesthesiologica Scandinavica
- Vol. 50 (5) , 562-567
- https://doi.org/10.1111/j.1399-6576.2006.001006.x
Abstract
In this study, we evaluated the learning curve and performance of the Viewmax laryngoscope during simulated difficult laryngoscopy in an intubation manikin (Laerdal Airway Management Trainer).To determine the learning curve, 25 anaesthesiologists without previous experience with the Viewmax laryngoscope performed 10 successive intubations in an intubation manikin with a normal airway. Time to intubation and failed intubation attempts were recorded. Another manikin was modified to enable comparison of the Viewmax laryngoscope with Macintosh and McCoy laryngoscopes. The time to intubation, number of failed intubation attempts, modified Cormack and Lehane (MCL) laryngeal view grading, percentage of glottic opening (POGO score), use of gum elastic bougie and subjective rating of degree of difficulty were recorded.The learning curve for the Viewmax laryngoscope showed a progressive decrease in time to successful intubation and reached a plateau at the sixth attempt. In simulated difficult laryngoscopy, the Viewmax laryngoscope demonstrated significantly better laryngeal view than the Macintosh and McCoy laryngoscopes in terms of MCL grading (Macintosh, P = 0.01; McCoy, P < 0.01) and POGO score (Macintosh, P < 0.01; McCoy, P < 0.01). The time required for intubation in simulated difficult laryngoscopy for the Viewmax laryngoscope was significantly longer than that for the Macintosh (P = 0.02) and McCoy (P < 0.01) laryngoscopes. There was no significant difference in the degree of difficulty, number of failed intubations and use of gum elastic bougie.When compared with the Macintosh and McCoy laryngoscopes in a manikin, the Viewmax laryngoscope appears to improve the view of the larynx but requires a longer time for tracheal intubation.Keywords
This publication has 17 references indexed in Scilit:
- Statistical evaluation of learning curve effects in surgical trialsClinical Trials, 2004
- A new mirrored laryngoscope*Anaesthesia, 2003
- Initial evaluation of a new optic laryngoscope bladeJournal of Clinical Anesthesia, 2002
- Modelling the difficult airway —how real is faking it?Canadian Journal of Anesthesia/Journal canadien d'anesthésie, 2002
- Evaluation of the use of the FlexibladeAnaesthesia, 2000
- difficult airway management: comparison of the bullard laryngoscope with the video-optical intubation styletCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 2000
- Assessment of Airway Visualization: Validation of the Percentage of Glottic Opening (POGO) ScaleAcademic Emergency Medicine, 1998
- An evaluation of the levering laryngoscopeAnaesthesia, 1996
- Difficult tracheal intubation in obstetricsAnaesthesia, 1984