The output of pulse-echo ultrasound equipment: a survey of powers, pressures and intensities
- 1 October 1985
- journal article
- research article
- Published by Oxford University Press (OUP) in The British Journal of Radiology
- Vol. 58 (694) , 989-1001
- https://doi.org/10.1259/0007-1285-58-694-989
Abstract
A survey of the powers, pressures and intensities generated by ultrasonic pulse-echo equipment in clinical use has bene carried out. Three conventional B-scanners four linear-array scanners and four mechanically sectored scanners were included in the study. Measurements were made on a total of 22 transducers covering the nominal frequency range 2.25-7.5 MHz. On those instruments where an output power control was provided, two measurements were made: one at the maximum available power and a second at a lower power. On arrays with a variable transmit focus control, measurements were made at all available focus settings. In all, measurements were made on 38 separate focused pulsed ultrasonic fields. The measurements were carried out using a calibrated ultrasonic force balance, and a calibrated polyvinylidene difluoride (PVdF) membrane hydrophone. A very wide range of maximum power pressures and intensities were found. Powers from 0.5-80 mW were measured; spatial-average temporal-peak positive pressure at the transducer varied between 30 kPa and 1.15 MPa and spatial-peak pulse-average intensities were in the range 3.6 .times. 103-1.1 .times. 107 W m-2.This publication has 9 references indexed in Scilit:
- Finite amplitude distortion of the pulsed fields used in diagnostic ultrasoundUltrasound in Medicine & Biology, 1984
- Acoustic shock generation by ultrasonic imaging equipmentThe British Journal of Radiology, 1984
- PVDF membrane hydrophone performance properties and their relevance to the measurement of the acoustic output of medical ultrasonic equipmentJournal of Physics E: Scientific Instruments, 1983
- Generation of transient cavities in liquids by microsecond pulses of ultrasoundThe Journal of the Acoustical Society of America, 1982
- On the plane-wave approximation of acoustic intensityThe Journal of the Acoustical Society of America, 1982
- A portable radiation-force balance for use with diagnostic ultrasonic equipmentUltrasound in Medicine & Biology, 1978
- Ultrasonic power and intensities produced by diagnostic ultrasound equipmentUltrasound in Medicine & Biology, 1978
- Calibration of ultrasonic beams for bio-medical applicationsPhysics in Medicine & Biology, 1970
- Balance Technique for the Measurement of Very Low Ultrasonic Power OutputsThe Journal of the Acoustical Society of America, 1965