Persistent Inhibition of Neointimal Hyperplasia After Sirolimus-Eluting Stent Implantation
Open Access
- 24 September 2002
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Circulation
- Vol. 106 (13) , 1610-1613
- https://doi.org/10.1161/01.cir.0000034447.02535.d5
Abstract
Background— Early results of sirolimus-eluting stent implantation showed a nearly complete abolition of neointimal hyperplasia. The question remains, however, whether the early promising results will still be evident at long-term follow-up. The objective of our study was to evaluate the efficiency of sirolimus-eluting stent implantation for up to 2 years of follow-up. Methods and Results— Fifteen patients with de novo coronary artery disease were treated with 18-mm sirolimus-eluting Bx-Velocity stents (Cordis) loaded with 140 μg sirolimus/cm 2 metal surface area in a slow release formulation. Quantitative angiography (QCA) and intravascular ultrasound (IVUS) were performed according to standard protocol. Sirolimus-eluting stent implantation was successful in all 15 patients. During the in-hospital course, 1 patient died of cerebral hemorrhage after periprocedural administration of abciximab, and 1 patient underwent repeat stenting after 2 hours because of edge dissection that led to acute occlusion. Through 6 months and up to 2 years of follow-up, no additional events occurred. QCA analysis revealed no significant change in stent minimal lumen diameter or percent diameter stenosis, and 3-dimensional IVUS showed no significant deterioration in lumen volume. In 2 patients, additional stenting was performed because of significant lesion progression remote from the sirolimus-eluting stent. Conclusion— Sirolimus-eluting stents showed persistent inhibition of neointimal hyperplasia for up to 2 years of follow-up.Keywords
This publication has 6 references indexed in Scilit:
- A Randomized Comparison of a Sirolimus-Eluting Stent with a Standard Stent for Coronary RevascularizationNew England Journal of Medicine, 2002
- Rapamycin eluting stent: the onset of a new era in interventional cardiologyHeart, 2002
- Coronary restenosis elimination with a sirolimus eluting stent; First European human experience with 6-month angiographic and intravascular ultrasonic follow-upEuropean Heart Journal, 2001
- Living the dream of no restenosis.Circulation, 2001
- The TRAPIST Study. A multicentre randomized placebo controlled clinical trial of trapidil for prevention of restenosis after coronary stenting, measured by 3-D intravascular ultrasoundEuropean Heart Journal, 2001
- Three-Year Follow-up after Implantation of Metallic Coronary-Artery StentsNew England Journal of Medicine, 1996