Influence of coronary vessel size on renarrowing process and late angiographic outcome after successful balloon angioplasty.
- 1 September 1994
- journal article
- abstracts
- Published by Wolters Kluwer Health in Circulation
- Vol. 90 (3) , 1239-1251
- https://doi.org/10.1161/01.cir.90.3.1239
Abstract
BACKGROUND Although coronary angioplasty is increasingly applied in the treatment of multivessel disease and a broadening range of vessel size, the influence of vessel size itself on the late results of intervention is unresolved. An influence of vessel size on late outcome would carry implications for the application and evaluation of interventional devices, which are selectively used in larger or smaller vessels. The purpose of the present study was to investigate the influence of vessel size on both the restenosis process and late angiographic outcome in a large homogeneous patient group after successful percutaneous transluminal coronary angioplasty (PTCA). METHODS AND RESULTS The study population comprised 3072 patients with 3736 successfully dilated native primary coronary artery lesions and satisfactory quantitative angiographic analysis in multiple identical projections before and after PTCA and at a 6-month follow-up. Late luminal loss, minimal luminal diameter (MLD) at follow-up, and net luminal gain, as well as percent diameter stenosis at follow-up, net gain in percent diameter stenosis, restenosis rates (according to three definitions), and net gain index, were all compared among nine equally sized groups (noniles) according to vessel size. A direct influence of vessel size on continuous measures of late result was also evaluated by linear regression. These evaluations provided conflicting information with no consistent influence of vessel size emerging. To elucidate the independent influence of vessel size on the restenosis process (late loss) and late angiographic outcome (MLD at follow-up), multiple linear regression analysis was performed taking into account luminal gain, preprocedural MLD, and lesion location. In this manner, vessel size was found to be exert a significantly positive influence on MLD at follow-up (P < .0001) and an equally negative effect on loss. Correcting for vessel size by using percent stenosis measurements led to an anticipated neutralization of this influence. Lesion location in the left anterior descending coronary artery was found to be independently associated with greater loss and smaller MLD at follow-up (P < .0001). CONCLUSIONS Increasing coronary vessel size was found to be independently predictive of decreasing late luminal loss and increasing follow-up MLD after successful balloon angioplasty. Apparently superior or inferior late angiographic results of new interventional devices may thus be explained in part by preferential use in larger or smaller vessels, respectively. Devices that can safely optimize the short-term result of intervention may realize their ultimate long-term value in larger coronary vessels.Keywords
This publication has 35 references indexed in Scilit:
- Morphologic changes during follow-up after successful percutaneous transluminal coronary balloon angioplasty: Quantitative angiographic analysis in 778 lesions—further evidence for the restenosis paradoxAmerican Heart Journal, 1994
- Usefulness of repeat coronary angiography 24 hours after successful balloon angioplasty to evaluate early luminal deterioration and facilitate quantitative analysisThe American Journal of Cardiology, 1993
- Restenosis revisited: Insights provided by quantitative coronary angiographyAmerican Heart Journal, 1993
- Visual versus quantitative assessment of the severity of coronary artery stenoses: Can the angiographer's eye be reeducated?American Heart Journal, 1993
- Can the same edge-detection algorithm be applied to on-line and off-line analysis systems? Validation of a new cinefilm-based geometric coronary measurement softwareAmerican Heart Journal, 1993
- Angiographic predictors of recurrence of restenosis after Wiktor stent implantation in native coronary arteriesThe American Journal of Cardiology, 1993
- Frequency and consequences of intimal hyperplasia in specimens retrieved by directional atherectomy of native primary coronary artery stenoses and subsequent restenosesThe American Journal of Cardiology, 1993
- Quantitative analysis of factors influencing late lumen loss and restenosis after directional coronary atherectomyThe American Journal of Cardiology, 1993
- Influence of vessel selection on the observed restenosis rate after endoluminal stenting or directional atherectomyThe American Journal of Cardiology, 1992
- Calibration using angiographic catheters as scaling devices — Importance of filming the catheters not filled with contrast mediumThe American Journal of Cardiology, 1992