Inadequacy of motion correction algorithms in functional MRI: Role of susceptibility‐induced artifacts
- 1 March 1997
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 7 (2) , 365-370
- https://doi.org/10.1002/jmri.1880070219
Abstract
Functional MR (fMR) has been useful in providing insight into the localization and detection of neural cortical activity. However, patient head motion is inevitable over the course of most fMR experiments. Although methods to align the control and activation fMR images may correct for some of this motional error, they will be incomplete in correcting for those that depend on spatial orientation. MR signal amplitude of structures that lie along air-tissue interfaces, for example, are sensitive to susceptibility errors introduced by their reorientation with respect to the main magnetic field. This analysis, using phantoms, cadaver brain, and volunteers, has shown that this reorientation between control and activation images can create regions of “false activation” that increase in area with rotation. Anatomic regions that are expected to be most affected by these susceptibility-induced magnetic field homogeneity variations are those adjacent to bone or air, such as the mesial and inferior temporal lobes and the inferior and anterior frontal lobes. Interpretation of “activation” in these areas on fMR studies must be performed with careful consideration of this important source of error.Keywords
This publication has 10 references indexed in Scilit:
- The intravascular contribution to fmri signal change: monte carlo modeling and diffusion‐weighted studies in vivoMagnetic Resonance in Medicine, 1995
- Theory of NMR signal behavior in magnetically inhomogeneous tissues: The static dephasing regimeMagnetic Resonance in Medicine, 1994
- Microscopic susceptibility variation and transverse relaxation: Theory and experimentMagnetic Resonance in Medicine, 1994
- Artifacts due to stimulus correlated motion in functional imaging of the brainMagnetic Resonance in Medicine, 1994
- Identification of vascular structures as a major source of signal contrast in high resolution 2D and 3D functional activation imaging of the motor cortex at l.5T preliminary resultsMagnetic Resonance in Medicine, 1993
- Processing strategies for time‐course data sets in functional mri of the human brainMagnetic Resonance in Medicine, 1993
- Functional brain mapping by blood oxygenation level-dependent contrast magnetic resonance imaging. A comparison of signal characteristics with a biophysical modelBiophysical Journal, 1993
- Rapid Automated Algorithm for Aligning and Reslicing PET ImagesJournal of Computer Assisted Tomography, 1992
- Oxygenation‐sensitive contrast in magnetic resonance image of rodent brain at high magnetic fieldsMagnetic Resonance in Medicine, 1990
- Susceptibility artefacts in NMR imagingMagnetic Resonance Imaging, 1985