Intraocular pressure measurement after penetrating keratoplasty: minified Goldmann applanation tonometer, pneumatonometer, and Tono-Pen versus manometry.
Open Access
- 1 September 1994
- journal article
- research article
- Published by BMJ in British Journal of Ophthalmology
- Vol. 78 (9) , 671-676
- https://doi.org/10.1136/bjo.78.9.671
Abstract
The accuracy of intraocular pressure measurement with the minified Goldmann applanation tonometer, the pneumatonometer, and the Tono-Pen tonometer were compared in post-mortem human eyes which had undergone penetrating keratoplasty. Enucleated post-mortem human eyes underwent same sized (7.75 mm) or 0.5 mm oversized (8.25 mm) autologous penetrating keratoplasty. Intraocular pressure was then set and measured manometrically while being determined successively with each tonometer over the range of 0-65 mm Hg. Linear regression analysis comparing tonometric and manometric readings showed: (1) minified Goldmann applanation tonometer-slope 0.985 and 0.944, intercept 1.64 and 2.55 mm Hg, correlation coefficient 0.99 and 0.99 in same sized and oversized grafted eyes respectively; (2) pneumatonometer-slope 1.008 and 0.990, intercept 3.37 and 3.69 mm Hg, correlation coefficient 0.99 and 0.98; (3) Tono-Pen-slope 1.061 and 1.002, intercept 5.01 and 4.06 mm Hg, correlation coefficient 0.97 and 0.98. We concluded that the minified Goldmann applanation tonometer is as accurate or more accurate than the pneumatonometer and the Tono-Pen in post-mortem post-keratoplasty human eyes, and may be an economical, convenient alternative to the latter two instruments in clinical practice.Keywords
This publication has 30 references indexed in Scilit:
- Tono-Pen tonometry in normal and in post-keratoplasty eyes.British Journal of Ophthalmology, 1992
- Evaluation of the Keeler Pulsair non‐contact tonometerActa Ophthalmologica, 1989
- Accuracy and Precision of the Tono-Pen in Measuring Intraocular Pressure After Keratoplasty and Epikeratophakia and in Scarred CorneasArchives of Ophthalmology (1950), 1988
- Comparison of the Tono-Pen to the Goldmann Applanation TonometerArchives of Ophthalmology (1950), 1988
- Clinical Comparison of the Oculab Tono-Pen to the Goldmann Applanation TonometerOphthalmology, 1987
- 'Minified' Goldmann Applanating Prism for Tonometry in Monkeys and HumansArchives of Ophthalmology (1950), 1980
- The PneumatonographArchives of Ophthalmology (1950), 1979
- APPLANATION TONOMETRY IN THE CONSCIOUS CYNOMOLGUS MONKEY (MACACA FASCICULARIS)Acta Ophthalmologica, 1976
- A Rapid Pneumatic Applanation TonometerArchives of Ophthalmology (1950), 1968
- FAST, AUTOMATIC, ELECTRONIC TONOMETERS BASED ON AN EXACT THEORYActa Ophthalmologica, 1959