Invited. Remember true FISP? a high SNR, near 1‐second imaging method for T2‐like contrast in interventional MRI at .2 T
- 1 January 1998
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 8 (1) , 203-208
- https://doi.org/10.1002/jmri.1880080134
Abstract
Clinical requirements for interventional MRI (I‐MRI) monitoring of needle placement or thermal ablation demand rapid (near‐real‐time) image acquisition rates, high spatial resolution, and T2 weighting. Experimental analysis performed earlier (see ref. 8) suggests that many sequences used for either rapid scanning or T2 weighting at high fields fail to meet both the speed (conventional spin echo [SE], turbo SE) or contrast (ie, fast low‐angle shot [FLASH], fast imaging with steady state precession [FISP]) requirements when used at .2 T. In this work, we revisited a number of pulse sequences advocated primarily for higher field applications requiring T2 weighting and found that refocused steady state coherent pulse sequences, aka, true FISP sequences, performed superiorly in achieving both speed and T2 contrast requirements for I‐MRI at .2 T. This work focuses on our experience with this new/old technique in the I‐MRI setting and describes how one can take advantage of the low field strength and modest inhomogeneity of .2 T (and similar) systems to design pulse sequences that balance TE, TR (and hence T2 dephasing), and resonant offset frequency effects to provide images with the desired contrast and minimal artifactual field inhomogeneity “banding.” At high flip angles (∼90°), reasonably short TEs (∼5 msec) and short TRs (∼ 10 msec), we have used this method in our last 25 I‐MRI procedures (biopsies and/or radiofrequency [RF] thermal ablations) and found these sequences to be extremely useful in both needle localization phases of I‐MRI biopsy procedures, RF thermal ablation electrode guidance, and posttherapy imaging assessment. Design methods and clinical I‐MRI cases are presented that highlight these points.Keywords
This publication has 11 references indexed in Scilit:
- MR-guided biopsy using ultrafast T1- and T2- weighted reordered turbo fast low-angle shot sequences: feasibility and preliminary clinical applications.American Journal of Roentgenology, 1996
- MR imaging-guided localization and biopsy of breast lesions: initial experience.Radiology, 1994
- MRI-Guided Laser-Induced Interstitial Thermotherapy of Cerebral NeoplasmsJournal of Computer Assisted Tomography, 1994
- Interventional MR imaging.RadioGraphics, 1993
- Monitoring of laser and freezinginduced ablation in the liver with T1‐weighted MR imagingJournal of Magnetic Resonance Imaging, 1992
- Motion‐insensitive, steady‐state free precession imagingMagnetic Resonance in Medicine, 1990
- Some factors that influence the steady state in steady-state free precessionMagnetic Resonance Imaging, 1988
- Flow suppression in rapid FLASH NMR imagesMagnetic Resonance in Medicine, 1987
- Rapid Fourier imaging using steady‐state free precessionMagnetic Resonance in Medicine, 1987
- FLASH imaging. Rapid NMR imaging using low flip-angle pulsesJournal of Magnetic Resonance (1969), 1986