Estimation of cardiac output by an N2O rebreathing method in adults and children
- 1 September 1976
- journal article
- research article
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 41 (3) , 433-438
- https://doi.org/10.1152/jappl.1976.41.3.433
Abstract
A nitrous oxide rebreathing method was used to measure recirculation time and cardiac output (as pulmonary blood flow) in adults and children during exercise. The method was compared with the indirect (CO2) Fick rebreathing method in almost simultaneous measurements of cardiac output. Recirculation time varied from about 15 s at rest to 8.5 s at high levels of exercise,and was slightly longer in children than adults. Cardiac output estimated by both methods was within the normal range for children and adults, being lower for a given oxygen consumption in children. For the adults the mean intrasubject variability of the N2O rebreathing method, measured as the coefficient of variation of cardiac output, was in the range of 6–8% at all levels of work. This was lower than reported for other N2O rebreathing methods,and similar to values based on the indirect (CO2) Fick, direct (O2) Fick, and dye-dilution methods of estimating cardiac output. The method is therefore proposed as a noninvasive technique suitable for rapid, accurate, and reproducible measurements of cardiac output.This publication has 15 references indexed in Scilit:
- Circulatory and Respiratory Adaptation, during Long‐Term, Non‐Steady State Exercise, in the Sitting Position1Acta Physiologica Scandinavica, 1964
- Cardiac output during submaximal and maximal workJournal of Applied Physiology, 1964
- Solubility of Acetylene in Lung Tissue as an Error in Cardiac Output Determination with the Acetylene MethodActa Physiologica Scandinavica, 1963
- Measurement of pulmonary blood flow during exercise using nitrous oxideJournal of Applied Physiology, 1962
- Pulmonary capillary blood volume, flow and diffusing capacity during exerciseJournal of Applied Physiology, 1960
- The Reproducibility of Cardiac Output Determination by the Direct Fick Method During Muscular WorkScandinavian Journal of Clinical and Laboratory Investigation, 1960
- Determination of pulmonary parenchymal tissue volume and pulmonary capillary blood flow in manJournal of Applied Physiology, 1959
- Exchange of Gases Between Alveolar Air and Pulmonary Capillary Blood: Pulmonary Diffusing CapacityPhysiological Reviews, 1957
- THE DETERMINATION OF THE CARDIAC OUTPUT OF MAN BY THE USE OF ACETYLENEAmerican Journal of Physiology-Legacy Content, 1929
- A METHOD FOR THE DETERMINATION OF THE CIRCULATORY MINUTE VOLUME IN MANAmerican Journal of Physiology-Legacy Content, 1928