Parts-Per-Billion Mass Measurement Accuracy Achieved through the Combination of Multiple Linear Regression and Automatic Gain Control in a Fourier Transform Ion Cyclotron Resonance Mass Spectrometer
- 1 June 2007
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 79 (13) , 5058-5063
- https://doi.org/10.1021/ac0704210
Abstract
Fourier transform ion cyclotron resonance mass spectrometry has the ability to achieve unprecedented mass measurement accuracy (MMA); MMA is one of the most significant attributes of mass spectrometric measurements as it affords extraordinary molecular specificity. However, due to space-charge effects, the achievable MMA significantly depends on the total number of ions trapped in the ion cyclotron resonance (ICR) cell for a particular measurement. Even through the use of automatic gain control (AGC), the total ion population is not constant between spectra. Multiple linear regression calibration in conjunction with AGC is utilized in these experiments to formally account for the differences in total ion population in the ICR cell between the external calibration spectra and experimental spectra. This ability allows for the extension of dynamic range of the instrument and for the mean MMA values to remain less than 1 part-per-million (ppm). In addition, multiple linear regression calibration is used to account for both differences in total ion population in the ICR cell as well as relative ion abundance of a given species, which also affords mean MMA values at the parts-per-billion (ppb) level.Keywords
This publication has 39 references indexed in Scilit:
- Optimization and Use of Peptide Mass Measurement Accuracy in Shotgun ProteomicsMolecular & Cellular Proteomics, 2006
- Characterization of Mouse Spleen Cells by Subtractive ProteomicsMolecular & Cellular Proteomics, 2005
- Statistical Evaluation of Internal and External Mass Calibration Laws Utilized in Fourier Transform Ion Cyclotron Resonance Mass SpectrometryAnalytical Chemistry, 2005
- Accurate mass measurements by Fourier transform mass spectrometryMass Spectrometry Reviews, 2004
- Routine Part-per-Million Mass Accuracy for High- Mass Ions: Space-Charge Effects in MALDI FT-ICRAnalytical Chemistry, 1998
- Resolution, Elemental Composition, and Simultaneous Monitoring by Fourier Transform Ion Cyclotron Resonance Mass Spectrometry of Organosulfur Species before and after Diesel Fuel ProcessingAnalytical Chemistry, 1998
- Masses of stable neon isotopes determined at parts per billion precision by Fourier transform ion cyclotron resonance mass spectrometryInternational Journal of Mass Spectrometry and Ion Processes, 1993
- Space charge effects in Fourier transform mass spectrometry. II. Mass calibrationAnalytical Chemistry, 1984
- Experimental determination of the effects of space charge on ion cyclotron resonance frequenciesInternational Journal of Mass Spectrometry and Ion Processes, 1983
- Theory of space-charge shift of ion cyclotron resonance frequenciesInternational Journal of Mass Spectrometry and Ion Processes, 1983