Added value of transoesophageal echocardiography during transseptal puncture performed by inexperienced operators
Open Access
- 23 November 2011
- journal article
- clinical trial
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 14 (5) , 661-665
- https://doi.org/10.1093/europace/eur366
Abstract
Transseptal puncture (TP) appears to be safe in experienced hands; however, it can be associated with life-threatening complications. The aim of our study was to demonstrate the added value of routine use of transoesophageal echocardiography (TEE) for the correct positioning of the transseptal system in the fossa ovalis, thus potentially preventing complications during fluoroscopy-guided TP performed by inexperienced operators. Two hundred and five patients undergoing pulmonary vein isolation procedure (PVI) for drug-resistant paroxysmal or persistent atrial fibrillation were prospectively included. When the operator (initially blinded to TEE) assumed that the transseptal system was in a correct position according to fluoroscopical landmarks, the latter was then checked with TEE unblinding the physician. If necessary, further refinement of the catheter position was performed. Refinement >10 mm, or in case of catheter pointing directly at the aortic root or posterior wall were considered as major repositioning. Thirty-four patients required major repositioning. Regression analysis revealed age (P: 0.0001, Wald: 12.9, 95% confidence interval: 1.04–1.16), left atrial diameter (P: 0.01, Wald: 6.6, 95% confidence interval: 1.04–1.34), previous PVI (P: 0.01, Wald: 6.3, 95% confidence interval: 1.31–8.76), and atrial septal thickness (P: 0.03, Wald: 4.5, 95% confidence interval: 1.05–3.4) as independent predictors of major revision with TEE. Routine 2D TEE in addition to traditional fluoroscopic TP appears to be very useful to guide the TP assembly in a correct puncture position and thus, to avoid TP-related complications. However, further randomized prospective comparative studies are necessary to support these suggestions.Keywords
This publication has 18 references indexed in Scilit:
- Updated Worldwide Survey on the Methods, Efficacy, and Safety of Catheter Ablation for Human Atrial FibrillationCirculation: Arrhythmia and Electrophysiology, 2010
- Interatrial Septum Thickness and Difficulty with Transseptal Puncture during Redo Catheter Ablation of Atrial FibrillationPacing and Clinical Electrophysiology, 2008
- Emerging Applications for Transseptal Left Heart Catheterization: Old Techniques for New ProceduresJournal of the American College of Cardiology, 2008
- The change in the fluoroscopy-guided transseptal puncture site and difficult punctures in catheter ablation of recurrent atrial fibrillationEP Europace, 2008
- Safety of Single Transseptal Puncture for Ablation of Atrial Fibrillation: Retrospective Study from a Large Cohort of PatientsJournal of Cardiovascular Electrophysiology, 2007
- Repeat Transseptal Catheterization After Ablation for Atrial FibrillationJournal of Cardiovascular Electrophysiology, 2006
- Electrophysiology of Pulmonary VeinsJournal of Cardiovascular Electrophysiology, 2005
- Shifting of Puncture Site in the Fossa Ovalis During Radiofrequency Catheter Ablation: Intracardiac Echocardiography-guided Transseptal Left Heart CatheterizationJapanese Heart Journal, 2003
- Spontaneous Initiation of Atrial Fibrillation by Ectopic Beats Originating in the Pulmonary VeinsNew England Journal of Medicine, 1998
- Transesophageal echocardiographically guided atrial transseptal catheterization in patients with normal‐sized atria: Incidence of complicationsClinical Cardiology, 1995