Cascade removal and microPET imaging with76Br
- 19 February 2009
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 54 (6) , 1503-1531
- https://doi.org/10.1088/0031-9155/54/6/008
Abstract
PET imaging with non-standard nuclides has limitations due to the reduced spatial resolution from the positron range and from the concurrent emission of other gamma rays during the decay process. Particularly in high-resolution small animal PET imaging, these factors become detrimental for accurate quantitation of the activity concentrations from the reconstructed images. This paper presents an evaluation for imaging with such a nuclide, (76)Br, through imaging of specifically designed phantoms in a high-resolution small animal PET scanner. A model is presented for the calculation and removal of fortuitous cascade gamma ray coincidences based on estimation of the activity distribution and the attenuation correction file. In this evaluation, it is shown that 2 mm spatial resolution can be achieved with (76)Br while 1.7 mm was achieved with (18)F using a filtered back projection algorithm despite the much higher end-point energy of the positrons from (76)Br. A detailed evaluation of the point spread function for this nuclide was fitted by a double Gaussian function and explained the long tail from the high-energy positrons. These evaluations are crucial for accurate correction for partial volume effects and to provide accurate measurement of the activity concentrations in small animal PET imaging.Keywords
This publication has 28 references indexed in Scilit:
- Performance Measurement of the microPET Focus 120 ScannerJournal of Nuclear Medicine, 2007
- Performance Evaluation of the microPET®—FOCUS-F120IEEE Transactions on Nuclear Science, 2007
- Advances in the production, processing and microPET image quality of technetium-94mNuclear Medicine and Biology, 2006
- GATE: a simulation toolkit for PET and SPECTPhysics in Medicine & Biology, 2004
- Quantitative imaging of bromine‐76 and yttrium‐86 with PET: A method for the removal of spurious activity introduced by cascade gamma raysMedical Physics, 2003
- MicroPET imaging with nonconventional isotopesIEEE Transactions on Nuclear Science, 2002
- PET quantitation and imaging of the non-pure positron-emitting iodine isotope 124IApplied Radiation and Isotopes, 2002
- Accurate condensed history Monte Carlo simulation of electron transport. II. Application to ion chamber response simulationsMedical Physics, 2000
- Accurate condensed history Monte Carlo simulation of electron transport. I. EGSnrc, the new EGS4 versionMedical Physics, 2000
- Exact and approximate rebinning algorithms for 3-D PET dataIEEE Transactions on Medical Imaging, 1997