Direct Octanol Water Partition Coefficient Determination Using Co-Current Chromatography
- 1 November 1992
- journal article
- research article
- Published by Taylor & Francis in Journal of Liquid Chromatography
- Vol. 15 (15) , 2769-2785
- https://doi.org/10.1080/10826079208016347
Abstract
Octanol-water partition coefficients. Koct, can be measured directly using countercurrent chromatography (CCC) with an octanol-water biphasic solvent system. The mobile phase is water saturated with octanol, and the stationary phase is octanol saturated with water. The measurable Koct range was 0.003 to 300. A liquid stationary octanol phase permits the development of a dual-mode elution method using CCC which extends the measurable Koct range to 5,000 (log Koct = 3.7). The co-current CCC method was developed to extend the range to Koct = 20,000 (log Koct = 4.3). In co-current CCC both the water and the octanol phase move in the same direction at different rates. Using the complete theory that was developed recently (Berthod, A. Analusis, 18, 352, 1990), it was possible to measure with a hydrostatic CCC apparatus loaded with 2 cartridges (800 channels, 49 mL. internal volume) the Koct values 10 solutes. The Koct values ranged from 11 (Phthalimide) to 20,000 (Phenanthrene). The continuous detection problem was solved by the post-column addition of 2-propanol as a solubilizing agent with mild heating. As predicted by the theory, the maximum Koct selectivity depends on the octanol to water flow rate ratio. It was found that the efficiency increases with octanol flow rate and. at a given octanol flow rate, the efficiency increases with the solute retention volume (or solute hydrophobicity). The continuous input of octanol at the head of the CCC apparatus produced an autofocusing effect which limits band broadening and peak tailing of the injected band of solute located in the octanol phase.Keywords
This publication has 10 references indexed in Scilit:
- Practical approach to high-speed counter-current chromatographyJournal of Chromatography A, 1991
- Countercurrent ChromatographyAnalytical Chemistry, 1991
- Countercurrent chromatographyAnalytical Chemistry, 1991
- Extended Octanol-Water Partition Coefficient Determination by Dual-Mode Centrifugal Partition ChromatographyJournal of Liquid Chromatography, 1990
- Direct Measurement of Octanol-Water Partition Coefficients Using Centrifugal Partition Chromatography with a Back-Flushing TechniqueJournal of Liquid Chromatography, 1990
- Assessment of Centrifugal Partition Chromatography for Determination of Octanol-Water Partition CoefficientsJournal of Liquid Chromatography, 1990
- Study of the origin and mechanism of band broadening and pressure drop in centrifugal countercurrent chromatographyAnalytical Chemistry, 1988
- Centrifugal Partition Chromatography. IV. Preparative Sample Purification and Partition Coefficient DeterminationJournal of Liquid Chromatography, 1988
- Centrifugal Partition Chromatography. V. Octanol-Water Partition Coefficients, Direct and Indirect DeterminationJournal of Liquid Chromatography, 1988
- Centrifugal Partition Chromatography. I. General FeaturesJournal of Liquid Chromatography, 1988