One-pass list-mode EM algorithm for high-resolution 3-D PET image reconstruction into large arrays
Top Cited Papers
- 10 December 2002
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 49 (3) , 693-699
- https://doi.org/10.1109/tns.2002.1039550
Abstract
High-resolution three-dimensional (3-D) positron emission tomography (PET) scanners with high count rate performance, such as the quad-high density avalanche chamber (HIDAC), place new demands on image reconstruction algorithms due to the large quantities of high-precision list-mode data which are produced. Therefore, a reconstruction algorithm is required which can, in a practical time frame, reconstruct into very large image arrays (submillimeter voxels, which range over a large field of view) whilst preferably retaining the precision of the data. This work presents an algorithm which meets these demands: one-pass list-mode expectation maximization (OPL-EM) algorithm. The algorithm operates directly on list-mode data, passes through the data once only, accounts for finite resolution effects in the system model, and can also include regularization. The algorithm performs multiple image updates during its single pass through the list-mode data, corresponding to the number of subsets that the data have been split into. The algorithm has been assessed using list-mode data from a quad-HIDAC and is compared to the analytic reconstruction method 3-D reprojection (RP) with 3-D filtered backprojection.Keywords
This publication has 14 references indexed in Scilit:
- LMIRA: list-mode iterative reconstruction algorithm for SPECTIEEE Transactions on Nuclear Science, 2001
- Performance evaluation of the microPET P4: a PET system dedicated to animal imagingPhysics in Medicine & Biology, 2001
- Fast accurate iterative reconstruction for low-statistics positron volume imagingPhysics in Medicine & Biology, 1998
- List-mode likelihood: EM algorithm and image quality estimation demonstrated on 2-D PETIEEE Transactions on Medical Imaging, 1998
- List-mode likelihoodJournal of the Optical Society of America A, 1997
- Fast gradient-based methods for Bayesian reconstruction of transmission and emission PET imagesIEEE Transactions on Medical Imaging, 1994
- Analytic 3D image reconstruction using all detected eventsIEEE Transactions on Nuclear Science, 1989
- Noise and Edge Artifacts in Maximum-Likelihood Reconstructions for Emission TomographyIEEE Transactions on Medical Imaging, 1987
- Fast calculation of the exact radiological path for a three‐dimensional CT arrayMedical Physics, 1985
- Maximum Likelihood Reconstruction for Emission TomographyIEEE Transactions on Medical Imaging, 1982