Automated Detection of Malaria-Associated Pseudoeosinophilia and Abnormal WBC Scattergram by the Sysmex XE-2100 Hematology Analyzer: A Clinical Study with 1,801 Patients and Real-Time Quantitative PCR Analysis in Vivax Malaria-Endemic Area
- 1 March 2010
- journal article
- Published by American Society of Tropical Medicine and Hygiene in The American Journal of Tropical Medicine and Hygiene
- Vol. 82 (3) , 412-414
- https://doi.org/10.4269/ajtmh.2010.09-0560
Abstract
Recently, the XE-2100 hematology analyzer was investigated in a rather small patient group; pseudoeosinophilia or abnormal white blood cell (WBC) scattergrams reported by this instrument were considered as significantly valuable diagnostic parameters in detecting vivax malaria. This study was conducted not only to assess the usefulness of pseudoeosinophilia or abnormal WBC scattergram in vivax malaria-endemic areas with large patient groups (N = 1,801) but also to investigate the correlation of parasitemia and platelet count with pseudoeosinophilia and abnormal WBC scattergrams. Of the 1,801 analyzed patients, 413 (22.9%) were found to have malaria by Wright–Giemsa stained blood smears. Overall, either pseudoeosinophilia or abnormal WBC scattergram was detected in 191 of 413 malaria patients and 4 of 1,388 patients without malaria (sensitivity = 46.2%, specificity = 99.7%). We suggest that clinical hematology laboratories using the XE-2100 analyzer should be aware of such specific parameters, even with the absence of a clinical request.Keywords
This publication has 17 references indexed in Scilit:
- Malaria detection with the Sysmex XE-2100 hematology analyzer using pseudoeosinophilia and abnormal WBC scattergramAnnals of Hematology, 2008
- Sensitivity of laser light depolarization analysis for detection of malaria in blood samplesJournal of Medical Microbiology, 2005
- Pseudoeosinophilia associated with malaria infection determined in the Sysmex XE-2100 hematology analyzerAnnals of Hematology, 2004
- Evaluation of the RealArt Malaria LC Real-Time PCR Assay for Malaria DiagnosisJournal of Clinical Microbiology, 2004
- Sensitivity of hemozoin detection by automated flow cytometry in non‐ and semi‐immune malaria patientsCytometry Part B: Clinical Cytometry, 2003
- Automated detection of malaria pigment in white blood cells for the diagnosis of malaria in Portugal.The American Journal of Tropical Medicine and Hygiene, 2001
- Automated Malaria Diagnosis Using Pigment DetectionParasitology Today, 2000
- Malaria diagnosis with the haematology analyser Cell-Dyn 3500™: What does the instrument detect?Clinical and Laboratory Haematology, 2000
- Automated malaria detection by depolarization of laser lightBritish Journal of Haematology, 1999
- Clearance kinetics of parasites and pigment-containing leukocytes in severe malariaBlood, 1996