Flow rate calibration I: A novel approach for performing absolute cell counts
- 22 August 2003
- journal article
- research article
- Published by Wiley in Cytometry Part B: Clinical Cytometry
- Vol. 55B (1) , 1-7
- https://doi.org/10.1002/cyto.b.10051
Abstract
Background: Reports suggest that flow rate (FR) is constant on bench top flow cytometers. Therefore, if FR is constant, the volume acquired in a fixed time period will also be constant, enabling absolute leucocyte counting using flow rate calibration (FRC).Methods: FR stability was ascertained on a standard FACSCalibur by counting TruCount beads suspended in phosphate buffered saline over 120 s. Studies using two lysing solutions (FACS lysing solution and PharM Lyse) and corresponding sample lysates established a lysing solution calibration factor (CF). Absolute CD4+T‐lymphocyte counts on 10 peripheral blood samples determined using FRC were compared with the predicate method TruCount/MultiTEST, incorporating MultiSET software. Linearity studies were also performed at three different flow rates.Results: A high degree of linearity over a wide range of counts (50 to >1,600 CD4+T lymphocytes/μl) at all three pressures was observed. Importantly, there was no significant difference from the predicate method when appropriate lysing solution CF was used.Conclusions: Using a simple calibration procedure and incorporation of an appropriate lysing solution CF, we show that FRC can easily be performed. The technical details that underpin this novel approach for absolute leucocyte enumeration are provided. Cytometry Part B (Clin. Cytometry) 55B:1–7, 2003.Keywords
This publication has 16 references indexed in Scilit:
- Flow rate calibration II: A clinical evaluation study using PanLeucoGating as a single-platform protocolCytometry, 2003
- Stability of currently used cytometers facilitates the identification of pipetting errors and their volumetric operation: ?Time? can tell allCytometry, 2003
- CD45‐assisted PanLeucogating for accurate, cost‐effective dual‐platform CD4+ T‐cell enumerationCytometry, 2002
- T‐cell subset counting and the fight against AIDS: Reflections over a 20‐year struggleCytometry, 2002
- Affordable CD4+ T-cell counts on ‘single-platform’ flow cytometers I. Primary CD4 gatingBritish Journal of Haematology, 2000
- Evaluation of TruCount Absolute-Count Tubes for Determining CD4 and CD8 Cell Numbers in Human Immunodeficiency Virus-Positive AdultsClinical and Diagnostic Laboratory Immunology, 2000
- Factors influencing haemopoietic recovery following chemotherapy-mobilised autologous peripheral blood progenitor cell transplantation for haematological malignancies: a retrospective analysis of a 10-year single institution experienceBone Marrow Transplantation, 1998
- Guidelines for the enumeration of CD4+ T lymphocytes in immunosuppressed individualsClinical and Laboratory Haematology, 1997
- Improved Priming for Mobilization of and Optimal Timing for Harvest of Peripheral Blood Stem CellsJournal of Hematotherapy, 1996
- Standardization of absolute CD4+ lymphocyte counts across laboratories: An evaluation of the ortho CytoronAbsolute flow cytometry system on normal donorsCytometry, 1995