The Paclitaxel-Eluting Stent in Percutaneous Coronary Intervention
- 1 March 2006
- journal article
- review article
- Published by Wolters Kluwer Health in Cardiology in Review
- Vol. 14 (2) , 88-98
- https://doi.org/10.1097/01.crd.0000200895.60631.0b
Abstract
The development of coronary artery stents that release (elute) a drug locally into the diseased vasculature has revolutionized the practice of interventional cardiology. These devices were designed to minimize the incidence of in-stent restenosis that may occur with bare metal stents. The paclitaxel-eluting stent is the most recent drug-eluting stent approved for use in the United States and is a bare metal stent coated with paclitaxel that is gradually released from the stent into the vessel wall with undetectable systemic concentrations of the drug. Paclitaxel functions to stabilize the assembly of microtubules, thereby interfering with cell division, motility, and shape, and ultimately inhibiting smooth muscle cell proliferation and migration, key processes in the development of neointimal hyperplasia during in-stent restenosis. Clinical trials have repeatedly demonstrated the superiority of the paclitaxel-eluting stent over the bare metal stent in terms of reducing restenosis rates and percent stenosis diameter as well as other angiographic end points. Although the rates of major adverse cardiac events are reduced with the paclitaxel-eluting stent compared with the bare metal stent, this is primarily the result of a reduction in the need for target vessel revascularization, whereas rates of myocardial infarction and death have not been shown to be significantly affected.Keywords
This publication has 50 references indexed in Scilit:
- Paclitaxel-eluting stents in coronary artery diseaseAmerican Journal of Health-System Pharmacy, 2005
- Comparison of neointimal formation in polymer-free paclitaxel stents versus stainless stents (from the ASPECT and ELUTES randomized clinical trials)The American Journal of Cardiology, 2004
- Drug-eluting stents: new era and new concernsPostgraduate Medical Journal, 2004
- IN-STENT STENOSIS: PATHOLOGY AND IMPLICATIONS FOR THE DEVELOPMENT OF DRUG ELUTING STENTSHeart, 2003
- State of the art in coronary interventionThe American Journal of Cardiology, 2003
- Percutaneous Coronary Intervention in the Current Era Compared With 1985–1986Circulation, 2000
- Arterial Remodeling After Coronary AngioplastyCirculation, 1996
- A Comparison of Balloon-Expandable-Stent Implantation with Balloon Angioplasty in Patients with Coronary Artery DiseaseNew England Journal of Medicine, 1994
- A Randomized Comparison of Coronary-Stent Placement and Balloon Angioplasty in the Treatment of Coronary Artery DiseaseNew England Journal of Medicine, 1994
- Nonoperative Dilatation of Coronary-Artery StenosisNew England Journal of Medicine, 1979