Attenuation correction in quantitative SPECT of cerebral blood flow: a Monte Carlo study
- 21 November 2000
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 45 (12) , 3847-3859
- https://doi.org/10.1088/0031-9155/45/12/324
Abstract
Monte Carlo simulation has been used to produce projections from a voxel-based brain phantom, simulating a 99mTc-HMPAO single photon emission computed tomography (SPECT) brain investigation. For comparison, projections free from the effects of attenuation and scattering were also simulated, giving ideal transaxial images after reconstruction. Three methods of attenuation correction were studied: (a) a pre-processing method, (b) a post-processing uniform method and (c) a post-processing non-uniform method using a density map. The accuracy of these methods was estimated by comparison of the reconstructed images with the ideal images using the normalized mean square error, NMSE, and quantitative values of the regional cerebral blood flow, rCBF. A minimum NMSE was achieved for the effective linear attenuation coefficient µeff = 0.07 (0.09) cm-1 for the uniformpre method, the effective mass attenuation coefficient µeff/ρ = 0.08 (0.10) cm2 g-1 for the uniformpost method and µeff/ρ = 0.12 (0.13) cm2 g-1 for the non-uniformpost method. Values in parentheses represent the case of dual-window scatter correction. The non-uniformpost method performed better, as measured by the NMSE, both with and without scatter correction. Furthermore, the non-uniformpost method gave, on average, more accurate rCBF values. Although the difference in rCBF accuracy was small between the various methods, the same method should be used for patient studies as for the reference material.Keywords
This publication has 14 references indexed in Scilit:
- Dual-window scatter correction and energy window setting in cerebral blood flow SPECT: a Monte Carlo studyPhysics in Medicine & Biology, 2000
- The relative contributions of scatter and attenuation corrections toward improved brain SPECT quantificationPhysics in Medicine & Biology, 1998
- Evaluation of attenuation corrections using Monte Carlo simulated lung SPECTPhysics in Medicine & Biology, 1998
- Selection of collimator for rCBF studies and evaluation of triple-headed SPET using noise-resolution plotsNuclear Medicine Communications, 1997
- A new method for the relative quantification of rCBF examined by 99Tcm-HMPAO SPECTNuclear Medicine Communications, 1994
- A direct measurement of skull attenuation for quantitative SPECTIEEE Transactions on Nuclear Science, 1993
- A Monte Carlo program for the simulation of scintillation camera characteristicsComputer Methods and Programs in Biomedicine, 1989
- Variation of the count‐dependent Metz filter with imaging system modulation transfer functionMedical Physics, 1986
- Tc‐99m attenuation coefficients in water‐filled phantoms determined with gamma camerasMedical Physics, 1984
- A Method for Attenuation Correction in Radionuclide Computed TomographyIEEE Transactions on Nuclear Science, 1978