Dual-window scatter correction and energy window setting in cerebral blood flow SPECT: a Monte Carlo study
- 23 October 2000
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 45 (11) , 3431-3440
- https://doi.org/10.1088/0031-9155/45/11/323
Abstract
The image quality in SPECT studies of the regional cerebral blood flow (rCBF) performed with 99mTc-HMPAO is degraded by scattered photons. The finite energy resolution of the gamma camera makes the detection of scattered photons unavoidable, and this is observed in the image as an impaired contrast between grey and white matter structures. In this work, a Monte Carlo simulated SPECT study of a realistic voxel-based brain phantom was used to evaluate the resulting contrast-to-noise ratio for a number of energy window settings, with and without the dual-window scatter correction. Values of the scaling factor k, used to obtain the fraction of scattered photons in the photopeak window, were estimated for each energy window. The use of a narrower, asymmetric, energy discrimination window improved the contrast, with a subsequent increase in statistical noise due to the lower number of counts. The photopeak-window setting giving the best contrast-to-noise ratio was found to be the same whether or not scatter correction was applied. Its value was 17% centred at 142 keV. At the optimum photopeak-window setting, the contrast was improved by using scatter correction, but the contrast-to-noise ratio was made worse.Keywords
This publication has 13 references indexed in Scilit:
- The relative contributions of scatter and attenuation corrections toward improved brain SPECT quantificationPhysics in Medicine & Biology, 1998
- Evaluation of attenuation corrections using Monte Carlo simulated lung SPECTPhysics in Medicine & Biology, 1998
- Selection of collimator for rCBF studies and evaluation of triple-headed SPET using noise-resolution plotsNuclear Medicine Communications, 1997
- Monte Carlo and experimental evaluation of accuracy and noise properties of two scatter correction methods for SPECTPhysics in Medicine & Biology, 1996
- Optimum tomographic reconstruction parameters for HMPAO brain SPET imaging: a practical approach based on subjective and objective indexesEuropean Journal of Nuclear Medicine and Molecular Imaging, 1995
- A practical method for incorporating scatter in a projector-backprojector for accurate scatter compensation in SPECTIEEE Transactions on Nuclear Science, 1993
- Scatter, Spatial Resolution, and Quantitative Recovery in High Resolution SPECTJournal of Computer Assisted Tomography, 1992
- A Monte Carlo program for the simulation of scintillation camera characteristicsComputer Methods and Programs in Biomedicine, 1989
- Scatter detection in SPECT imaging: dependence on source depth, energy, and energy windowPhysics in Medicine & Biology, 1988
- Average soft-tissue and bone models for use in radiation dosimetryThe British Journal of Radiology, 1987