Analysis of noise properties of a class of exact methods of inverting the 2-D exponential radon transform [SPECT application]
- 1 January 1995
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 14 (4) , 659-668
- https://doi.org/10.1109/42.476107
Abstract
A general approach that the authors proposed elsewhere reveals the intrinsic relationship among methods for inversion of the 2-D exponential Radon transform described by Bellini et al. (1979), by Tretiak and Metz (1980), by Hawkins et al. (1988), and by Inouye et al. (1989). Moreover, the authors' approach provides an infinite class of linear methods for inverting the 2-D exponential Radon transform. In the work reported here, the authors systematically investigated the noise characteristics of the methods in this class, obtaining analytical forms for the autocovariance and the variance of the images reconstructed by use of various methods. The noise properties of a new "quasi-optimal" method were then compared theoretically to those of other methods of the class. The authors' analysis demonstrates that the quasi-optimal method achieves smaller global variance in the reconstructed images than do the other methods of the class. Extensive numerical simulation studies confirm this prediction.Keywords
This publication has 13 references indexed in Scilit:
- Noise properties of attenuation correction methods for SPECTPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2005
- A unified analysis of exact methods of inverting the 2-D exponential radon transform, with implications for noise control in SPECTIEEE Transactions on Medical Imaging, 1995
- Simultaneous correction of attenuation and distance-dependent resolution in SPECT: an analytical approachPhysics in Medicine & Biology, 1993
- SPECT reconstruction by simulated annealingPhysics in Medicine & Biology, 1989
- Image reconstruction algorithm for single-photon-emission computed tomography with uniform attenuationPhysics in Medicine & Biology, 1989
- The circular harmonic transform for SPECT reconstruction and boundary conditions on the Fourier transform of the sinogramIEEE Transactions on Medical Imaging, 1988
- Reconstruction of objects from coded images by simulated annealingOptics Letters, 1983
- The Use of Filtering Methods to Compensate for Constant Attenuation in Single-Photon Emission Computed TomographyIEEE Transactions on Biomedical Engineering, 1981
- The Exponential Radon TransformSIAM Journal on Applied Mathematics, 1980
- Compensation of tissue absorption in emission tomographyIEEE Transactions on Acoustics, Speech, and Signal Processing, 1979