Verification of lung dose in an anthropomorphic phantom calculated by the collapsed cone convolution method
- 23 October 2000
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 45 (11) , N143-N149
- https://doi.org/10.1088/0031-9155/45/11/402
Abstract
Verification of calculated lung dose in an anthropomorphic phantom is performed using two dosimetry media. Dosimetry is complicated by factors such as variations in density at slice interfaces and appropriate position on CT scanning slice to accommodate these factors. Dose in lung for a 6 MV and 10 MV anterior-posterior field was calculated with a collapsed cone convolution method using an ADAC Pinnacle, 3D planning system. Up to 5% variations between doses calculated at the centre and near the edge of the 2 cm phantom slice positioned at the beam central axis were seen, due to the composition of each phantom slice. Validation of dose was performed with LiF thermoluminescent dosimeters (TLDs) and X-Omat V radiographic film. Both dosimetry media produced dose results which agreed closely with calculated results nearest their physical positioning in the phantom. The collapsed cone convolution method accurately calculates dose within inhomogeneous lung regions at 6 MV and 10 MV x-ray energy.Keywords
This publication has 22 references indexed in Scilit:
- The impact of electron transport on the accuracy of computed doseMedical Physics, 2000
- American Association of Physicists in Medicine Radiation Therapy Committee Task Group 53: Quality assurance for clinical radiotherapy treatment planningMedical Physics, 1998
- Superposition dose calculation incorporating Monte Carlo generated electron track kernelsMedical Physics, 1996
- Accounting for the variation in collision kerma-to-terma ratio in polyenergetic photon beam convolutionMedical Physics, 1995
- Accounting for primary electron scatter in x-ray beam convolution calculationsMedical Physics, 1995
- Pitfalls in the use of high energy X rays to treat tumors in the lungInternational Journal of Radiation Oncology*Biology*Physics, 1990
- Collapsed cone convolution of radiant energy for photon dose calculation in heterogeneous mediaMedical Physics, 1989
- Calculation of photon dose distributions in an inhomogeneous medium using convolutionsMedical Physics, 1986
- A photon dose distribution model employing convolution calculationsMedical Physics, 1985
- A solid water phantom material for radiotherapy x-ray and γ-ray beam calibrationsMedical Physics, 1982