Contrast-enhanced, three-dimensional, whole-brain, black-blood imaging: Application to small brain metastases
- 25 February 2010
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 63 (3) , 553-561
- https://doi.org/10.1002/mrm.22261
Abstract
Contrast‐enhanced three‐dimensional T1‐weighted imaging based on magnetization‐prepared rapid‐gradient recalled echo is widely used for detecting small brain metastases. However, since contrast materials remain in both blood and the tumor parenchyma and thus increase the signal intensity of both regions, it is often challenging to distinguish brain tumors from blood. In this work, we develop a T1‐weighted, black‐blood version of single‐slab three‐dimensional turbo/fast spin echo whole‐brain imaging, in which the signal intensity of the brain tumor is selectively enhanced while that of blood is suppressed. For blood suppression, variable refocusing flip angles with flow‐sensitizing gradients are employed. To avoid a signal loss resulting from the flow‐sensitizing scheme, the first refocusing flip angle is forced to 180°. Composite restore pulses at the end of refocusing pulse train are applied to achieve partial inversion recovery for the T1‐weighted contrast. Simulations and in vivo volunteer and patient experiments are performed, demonstrating that this approach is highly efficient in detecting small brain metastases. Magn Reson Med 63:553–561, 2010.Keywords
Funding Information
- Korean government (2009-0075409)
- Yonsei University College of Medicine (6-2008-0110)
This publication has 16 references indexed in Scilit:
- Effective motion‐sensitizing magnetization preparation for black blood magnetic resonance imaging of the heartJournal of Magnetic Resonance Imaging, 2008
- Optimized T1‐weighted contrast for single‐slab 3D turbo spin‐echo imaging with long echo trains: Application to whole‐brain imagingMagnetic Resonance in Medicine, 2007
- Improved suppression of plaque‐mimicking artifacts in black‐blood carotid atherosclerosis imaging using a multislice motion‐sensitized driven‐equilibrium (MSDE) turbo spin‐echo (TSE) sequenceMagnetic Resonance in Medicine, 2007
- Non-CPMG Fast Spin Echo with Full SignalJournal of Magnetic Resonance, 2002
- Magnetic resonance imaging of the brain with gadopentetate dimeglumine-DTPA: Comparison of T1-weighted spin-echo and 3D gradient-echo sequencesJournal of Magnetic Resonance Imaging, 1996
- Improved contrast of enhancing brain lesions on postgadolinium, T1-weighted spin-echo images with use of magnetization transfer.Radiology, 1994
- High‐speed black blood imaging of vessel stenosis in the presence of pulsatile flowJournal of Magnetic Resonance Imaging, 1992
- Three‐dimensional magnetization‐prepared rapid gradient‐echo imaging (3D MP RAGE)Magnetic Resonance in Medicine, 1990
- Spatial presaturation: a method for suppressing flow artifacts and improving depiction of vascular anatomy in MR imaging.Radiology, 1987