Use of a common standard improves the performance of liquid chromatography-tandem mass spectrometry methods for serum 25-hydroxyvitamin-D
- 1 January 2009
- journal article
- Published by SAGE Publications in Annals of Clinical Biochemistry: International Journal of Laboratory Medicine
- Vol. 46 (1) , 79-81
- https://doi.org/10.1258/acb.2008.008135
Abstract
Background: Liquid chromatography-tandem mass spectrometry (LC-MS/MS) is becoming increasingly popular for measuring 25-hydroxyvitamin-D (25-OH-D). Results submitted to the International Quality Assessment Scheme (DEQAS) have shown poor interlaboratory agreement. We investigated whether the use of a common standard would reduce interlaboratory imprecision. Methods: A commercial standard and two controls were distributed with the DEQAS samples in January 2008. Participants were asked to calculate the results of samples and controls using their usual standard and the commercial standard. A method questionnaire was also distributed. Results: Use of a common standard reduced the mean interlaboratory imprecision (coefficient of variation [CV]) for total 25-OH-D from 16.4% (in-house standards) to 10.4% (common standard). For 25-OH-D3 and 25-OH-D2, the mean CVs were reduced from 16.7% and 21.1% to 8.5% and 12.6%, respectively. Mean values obtained for total 25-OH-D using the common standard were higher by 6.1%. Conclusions: Use of a common standard improved agreement among laboratories using LC-MS/MS methods for 25-OH-D. This suggests that problems with assay standardization contribute to interlaboratory imprecision. This may be related to the nature of the matrix used for working standards or errors in the calibration of stock standard solutions of 25-OH-D. Some participants used a gravimetric method, others UV spectrophotometry, to establish the concentration of stock solutions. Among the latter group there was uncertainty over the molar absorption coefficient of 25-OH-D solutions. We conclude that LC-MS/MS is not yet sufficiently robust to become the reference method for 25-OH-D and that gas chromatography-mass spectrometry might be a more suitable candidate.Keywords
This publication has 5 references indexed in Scilit:
- Measurement of 25-hydroxyvitamin D3 (25OHD3) and 25-hydroxyvitamin D2 (25OHD2) in human serum using liquid chromatography-tandem mass spectrometry and its comparison to a radioimmunoassay methodClinica Chimica Acta; International Journal of Clinical Chemistry, 2008
- Evaluation of a Candidate Reference Measurement Procedure for Serum Free Testosterone Based on Ultrafiltration and Isotope Dilution–Gas Chromatography–Mass SpectrometryClinical Chemistry, 2004
- Candidate Reference Method for the Quantification of Circulating 25-Hydroxyvitamin D3 by Liquid Chromatography–Tandem Mass SpectrometryClinical Chemistry, 2004
- Measurement of Vitamin D metabolites: an international perspective on methodology and clinical interpretationThe Journal of Steroid Biochemistry and Molecular Biology, 2004