Monitoring of heparin and its low-molecular-weight analogs by silicon field effect
- 5 September 2006
- journal article
- research article
- Published by Proceedings of the National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 103 (36) , 13374-13379
- https://doi.org/10.1073/pnas.0604471103
Abstract
Heparin is a highly sulfated glycosaminoglycan that is used as an important clinical anticoagulant. Monitoring and control of the heparin level in a patient's blood during and after surgery is essential, but current clinical methods are limited to indirect and off-line assays. We have developed a silicon field-effect sensor for direct detection of heparin by its intrinsic negative charge. The sensor consists of a simple microfabricated electrolyte-insulator-silicon structure encapsulated within microfluidic channels. As heparin-specific surface probes the clinical heparin antagonist protamine or the physiological partner antithrombin III were used. The dose-response curves in 10% PBS revealed a detection limit of 0.001 units/ml, which is orders of magnitude lower than clinically relevant concentrations. We also detected heparin-based drugs such as the low-molecular-weight heparin enoxaparin (Lovenox) and the synthetic pentasaccharide heparin analog fondaparinux (Arixtra), which cannot be monitored by the existing near-patient clinical methods. We demonstrated the specificity of the antithrombin III functionalized sensor for the physiologically active pentasaccharide sequence. As a validation, we showed correlation of our measurements to those from a colorimetric assay for heparin-mediated anti-Xa activity. These results demonstrate that silicon field-effect sensors could be used in the clinic for routine monitoring and maintenance of therapeutic levels of heparin and heparin-based drugs and in the laboratory for quantitation of total amount and specific epitopes of heparin and other glycosaminoglycans.Keywords
This publication has 51 references indexed in Scilit:
- Label-Free Microelectronic PCR QuantificationAnalytical Chemistry, 2006
- Voltammetric Detection of Heparin at Polarized Blood Plasma/1,2-Dichloroethane InterfacesAnalytical Chemistry, 2005
- Two mathematical models for the correction of carbohydrate and protein interference in the determination of uronic acids by them‐hydroxydiphenyl methodBiotechnology and Applied Biochemistry, 2005
- Syndecans and HIV-1 pathogenesisMicrobes and Infection, 2004
- Physical adsorption of protamine for heparin assay using a quartz crystal microbalance and electrochemical impedance spectroscopyAnalytica Chimica Acta, 2002
- Development of an ion-channel sensor for heparin detectionAnalytica Chimica Acta, 2000
- Low-Molecular-Weight HeparinsNew England Journal of Medicine, 1997
- Extraction Thermodynamics of Polyanions into Plasticized Polymer Membranes Doped with Lipophilic Ion Exchangers: A Potentiometric StudyMacromolecules, 1995
- Low molecular weight heparin treatment of venous thromboembolismProgress in Cardiovascular Diseases, 1994
- Development of an ISFET based heparin sensor using the ion-step measuring methodBiosensors and Bioelectronics, 1993