Quasiparticle diffusion and the energy resolution of superconducting tunneling junctions as photon detectors. I. Theory
- 13 September 2002
- journal article
- research article
- Published by American Physical Society (APS) in Physical Review B
- Vol. 66 (9) , 094510
- https://doi.org/10.1103/physrevb.66.094510
Abstract
One of the factors that degrades the energy resolution of superconducting tunnel junctions (STJ’s) as photon detectors at energies above a few keV is the spatial dependence of the response on the photoabsorption site. To assess the role of spatial inhomogeneities we have analyzed quasiparticle diffusion processes in detail and developed a general analytical theory to describe the evolution of the quasiparticle density in an STJ. This theory underlies an analytical model of the STJ response surface, and the corresponding spectral line shape. It accounts for effects of quasiparticle recombination, multiple quasiparticle tunneling, phonon coupling between the electrodes, asymmetry between base and counter electrode, losses at edges and localized traps, and diffusive losses into electrical connections, and is structured such that the effect of these features are added independently, so that the influence of each process can be assessed independently and possible new processes can easily be included.Keywords
This publication has 22 references indexed in Scilit:
- Experimental imaging diagnosis of superconducting tunnel junction x-ray detectors by low-temperature scanning synchrotron microscopeApplied Physics Letters, 2000
- Super photon countersNature, 1999
- High resolution tunnel junction extreme ultraviolet detectors limited by quasiparticle counting statisticsIEEE Transactions on Applied Superconductivity, 1999
- Use of hafnium-based superconducting tunnel junctions as high-resolution spectrometers for x-ray astronomyPublished by SPIE-Intl Soc Optical Eng ,1998
- Single photon detection at visible and x-ray wavelengths with Nb–Al superconducting tunnel junctionsJournal of Applied Physics, 1998
- Quasiparticle diffusion and loss processes in superconducting tunnel junctionsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1996
- Response of niobium-based superconducting tunnel junctions in the soft-x-ray region 0.15–6.5 keVPhysical Review B, 1996
- Statistical noise due to tunneling in superconducting tunnel junction detectorsApplied Physics Letters, 1994
- Energy-resolving superconducting x-ray detectors with charge amplification due to multiple quasiparticle tunnelingApplied Physics Letters, 1993
- Ionization Yield of Radiations. II. The Fluctuations of the Number of IonsPhysical Review B, 1947