Design of an interface to allow microfluidic electrophoresis chips to drink from the fire hose of the external environment
- 17 January 2001
- journal article
- research article
- Published by Wiley in Electrophoresis
- Vol. 22 (2) , 318-327
- https://doi.org/10.1002/1522-2683(200101)22:2<318::aid-elps318>3.0.co;2-g
Abstract
An interface design is presented that facilitates automated sample introduction into an electrokinetic microchip, without perturbing the liquids within the microfluidic device. The design utilizes an interface flow channel with a volume flow resistance that is 0.54—4.1 × 106 times lower than the volume flow resistance of the electrokinetic fluid manifold used for mixing, reaction, separation, and analysis. A channel, 300 μm deep, 1 mm wide and 15—20 mm long, was etched in glass substrates to create the sample introduction channel (SIC) for a manifold of electrokinetic flow channels in the range of 10—13 μm depth and 36—275 μm width. Volume flow rates of up to 1 mL/min were pumped through the SIC without perturbing the solutions within the electrokinetic channel manifold. Calculations support this observation, suggesting a leakage flow to electroosmotic flow ratio of 0.1:1% in the electrokinetic channels, arising from 66—700 μL/min pressure‐driven flow rates in the SIC. Peak heights for capillary electrophoresis separations in the electrokinetic flow manifold showed no dependence on whether the SIC pump was on or off. On‐chip mixing, reaction and separation of anti‐ovalbumin and ovalbumin could be performed with good quantitative results, independent of the SIC pump operation. Reproducibility of injection performance, estimated from peak height variations, ranged from 1.5—4%, depending upon the device design and the sample composition.Keywords
This publication has 26 references indexed in Scilit:
- A miniature integrated device for automated multistep genetic assaysNucleic Acids Research, 2000
- Microchip Device for Cell Lysis, Multiplex PCR Amplification, and Electrophoretic SizingAnalytical Chemistry, 1998
- Microchip Device for Performing Enzyme AssaysAnalytical Chemistry, 1997
- Integrated Capillary Electrophoresis Devices with an Efficient Postcolumn Reactor in Planar Quartz and Glass ChipsAnalytical Chemistry, 1996
- Functional Integration of PCR Amplification and Capillary Electrophoresis in a Microfabricated DNA Analysis DeviceAnalytical Chemistry, 1996
- Precolumn Reactions with Electrophoretic Analysis Integrated on a MicrochipAnalytical Chemistry, 1994
- Three-dimensional micro flow manifolds for miniaturized chemical analysis systemsJournal of Micromechanics and Microengineering, 1994
- Microchip Capillary Electrophoresis with an Integrated Postcolumn ReactorAnalytical Chemistry, 1994
- Micromachining a Miniaturized Capillary Electrophoresis-Based Chemical Analysis System on a ChipScience, 1993
- Micromachining of monocrystalline silicon and glass for chemical analysis systems A look into next century's technology or just a fashionable craze?TrAC Trends in Analytical Chemistry, 1991