DNA Extraction Using a Tetramethyl Orthosilicate-Grafted Photopolymerized Monolithic Solid Phase
- 20 January 2006
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 78 (5) , 1673-1681
- https://doi.org/10.1021/ac051796t
Abstract
A novel high-capacity, high-efficiency DNA extraction method is described using a photopolymerized silica-based monolithic column in a fused-silica capillary. Development involved investigation of the composition of the sol−gel monomer, fabrication conditions, and surface modifications in order to optimize the binding capacity. Extraction capacity and efficiency with the 3-(trimethoxysilyl)propyl methacrylate (TMSPM) monolith formulations fabricated in capillaries were investigated using a simple three-step procedure consisting of sample loading, washing of the solid phase, and elution of the DNA using a low ionic strength Tris buffer at pH 8. Once the TMSPM monomer concentration was optimized to yield a monolith with maximum test stability (robustness) and minimum back pressure, the monolith surface was modified by the grafting of tetramethyl orthosilicate (TMOS) for increased DNA binding capacity. After the examination of a variety of TMOS concentrations, 85% v/v TMOS was found to be optimal for DNA extraction without any obvious changes to the monolith structure. The reduction of time allowed for TMSPM hydrolysis prior to UV polymerization from 20 to 5 min led to a lower back pressure of the monolith, enabling better TMOS derivatization and therefore higher binding capacity. Minimal buffer volume (as low as 1 μL) was required to elute DNA from the solid phase, providing a DNA concentrating effect potentially important for downstream processes. While experimentation employed monolithic columns that were 12 cm in length, reduction of the length to 2 cm still allowed for a DNA binding capacity of at least 100 ng of prepurified human genomic DNA and extraction efficiencies greater than 85%. Extraction of low sample volumes (submicroliter) of human whole blood were successfully performed, with extraction efficiencies from the 2-cm monolithic column higher than those obtained from a commercial DNA extraction kit. These results position this novel matrix as an attractive alternative for solid-phase extraction of DNA and other biologically active molecules in microscale devices.Keywords
This publication has 28 references indexed in Scilit:
- Separation of Sperm and Epithelial Cells in a Microfabricated Device: Potential Application to Forensic Analysis of Sexual Assault EvidenceAnalytical Chemistry, 2004
- Integrated selective enrichment target – a microtechnology platform for matrix‐assisted laser desorption/ionization‐mass spectrometry applied on protein biomarkers in prostate diseasesElectrophoresis, 2004
- Shielded Stationary Phases Based on Porous Polymer Monoliths for the Capillary Electrochromatography of Highly Basic BiomoleculesAnalytical Chemistry, 2004
- Improved solid‐phase microextraction device for use in on‐line immunoaffinity capillary electrophoresisElectrophoresis, 2003
- Developments toward a complete micro-total analysis system for Duchenne muscular dystrophy diagnosisAnalytica Chimica Acta, 2003
- Photografting and the Control of Surface Chemistry in Three-Dimensional Porous Polymer MonolithsMacromolecules, 2003
- Toward sol-gel electrochromatographic separations on a chipJournal of Separation Science, 2002
- Photopolymerized Sol−Gel Monoliths for Capillary ElectrochromatographyAnalytical Chemistry, 2001
- Trapping of Bead-Based Reagents within Microfluidic Systems: On-Chip Solid-Phase Extraction and ElectrochromatographyAnalytical Chemistry, 1999
- Molded continuous poly(styrene-co-divinylbenzene) rod as a separation medium for the very fast separation of polymers Comparison of the chromatographic properties of the monolithic rod with columns packed with porous and non-porous beads in high-performance liquid chromatography of polystyrenesJournal of Chromatography A, 1996