Persistence of Pulmonary Vein Isolation After Robotic Remote‐Navigated Ablation for Atrial Fibrillation and its Relation to Clinical Outcome
- 23 April 2010
- journal article
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 21 (10) , 1079-1084
- https://doi.org/10.1111/j.1540-8167.2010.01773.x
Abstract
A robotic navigation system (RNS, Hansen™) has been developed as an alternative method of performing ablation for atrial fibrillation (AF). Despite the growing application of RNS-guided pulmonary vein isolation (PVI), its consequences and mechanisms of subsequent AF recurrences are unknown. We investigated the acute procedural success and persistence of PVI over time after robotic PVI and its relation to clinical outcome. Sixty-four patients (60.7 ± 9.8 years, 53 male) with paroxysmal AF underwent robotic circumferential PVI with 3-dimensional left atrial reconstruction (NavX™). A voluntary repeat invasive electrophysiological study was performed 3 months after ablation irrespective of clinical course. Robotic PVI was successful in all patients without complication (fluoroscopy time: 23.5 [12-34], procedure time: 180 [150-225] minutes). Fluoroscopy time demonstrated a gradual decline but was significantly reduced after the 30th patient following the introduction of additional navigation software (34 [29-45] vs 12 [9-17] minutes; P < 0.001). A repeat study at 3 months was performed in 63% of patients and revealed electrical conduction recovery in 43% of all PVs. Restudied patients without AF recurrence (n = 28) showed a significantly lower number of recovered PVs (1 (0-2) vs 2 (2-3); P = 0.006) and a longer LA-PV conduction delay than patients with AF recurrences (n = 12). Persistent block of all PVs was associated with freedom from AF in all patients. At 3 months, 67% of patients were free of AF, while reablation of recovered PVs led to an overall freedom from AF in 81% of patients after 1 year. Robotic PVI for PAF is safe, effective, and requires limited fluoroscopy while yielding comparable success rates to conventional ablation approaches with PV reconduction as a common phenomenon associated with AF recurrences.Keywords
This publication has 20 references indexed in Scilit:
- Remote Robotic Navigation and Electroanatomical Mapping for Ablation of Atrial FibrillationCirculation: Arrhythmia and Electrophysiology, 2009
- Relationship Between Catheter Forces, Lesion Characteristics, “Popping,” and Char Formation: Experience with Robotic Navigation SystemJournal of Cardiovascular Electrophysiology, 2009
- The impact of image integration on catheter ablation of atrial fibrillation using electroanatomic mapping: a prospective randomized studyEuropean Heart Journal, 2008
- State of the Art: Catheter Ablation of Atrial FibrillationJournal of Cardiovascular Electrophysiology, 2008
- Experience of robotic catheter ablation in humans using a novel remotely steerable catheter sheathJournal of Interventional Cardiac Electrophysiology, 2008
- View-Synchronized Robotic Image-Guided Therapy for Atrial Fibrillation AblationCirculation, 2007
- Characterization of Conduction Recovery Across Left Atrial Linear Lesions in Patients with Paroxysmal and Persistent Atrial FibrillationJournal of Cardiovascular Electrophysiology, 2006
- Virtual Anatomy for Atrial Fibrillation AblationJournal of Cardiovascular Electrophysiology, 2006
- Response of Atrial Fibrillation to Pulmonary Vein Antrum Isolation Is Directly Related to Resumption and Delay of Pulmonary Vein ConductionCirculation, 2005
- Prospective Assessment of Late Conduction Recurrence Across Radiofrequency Lesions Producing Electrical Disconnection at the Pulmonary Vein Ostium in Patients With Atrial FibrillationCirculation, 2003