One year results of European multicenter study of intrastromal corneal ring segments
- 1 February 2001
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 27 (2) , 277-286
- https://doi.org/10.1016/s0886-3350(00)00749-5
Abstract
To assess the efficacy, predictability, stability, and safety of correcting myopia with intrastromal corneal ring segments (ICRS, KeraVision, Inc.). Twelve European investigational sites. Patients with myopia of -1.0 to -6.0 diopters (D) and best spectacle-corrected visual acuity (BSCVA) of 20/20 or better (except in 3 eyes) were assigned to receive 1 of 5 ICRS thicknesses (0.25, 0.30, 0.35, 0.40, or 0.45 mm). Efficacy was assessed by postoperative uncorrected visual acuity (UCVA), predictability of refractive outcome (deviation from predicted cycloplegic refraction spherical equivalent), and stability of refractive effect (manifest refraction spherical equivalent [MRSE]). Safety was assessed by maintenance or loss of preoperative BSCVA and induced manifest refraction cylinder. Measurements were made preoperatively and 1 and 7 days and 1, 2, 3, 6, and 12 months postoperatively. One hundred fifty-nine ICRSs were implanted in the eyes of 107 patients (52 patients had bilateral implantation). Preoperatively, UCVA was worse than 20/40 in 98% of eyes (155/159); 12 months postoperatively, it was 20/20 or better in 63% of eyes (83/132) and 20/40 or better in 96% (127/132). Predicted refractive corrections for each ICRS thickness generally correlated with achieved corrections. At 12 months postoperatively, 90% of eyes (124/138) were within +/-1.00 D of plano (MRSE). Two or more lines of BSCVA were lost in 6% of eyes (8/135); all 8 eyes had BSCVAs of 20/25 or better. The ICRS safely, effectively, and predictably reduced or eliminated low to moderate myopia. Refractive correction was stable through the 12 month follow-up.Keywords
This publication has 13 references indexed in Scilit:
- Goldmann applanation tonometry after Intacs corneal ring segmentsJournal of Cataract & Refractive Surgery, 2000
- Intrastromale Corneale Ringsegmente (ICRS®, KeraVision Ring®, Intacs™): Klinische Ergebnisse nach 2 Jahren*Klinische Monatsblätter für Augenheilkunde, 2000
- Intrastromale Corneale Ring Segmente (ICRS®, KeraVision®Ring) - Einjahresergebnisse der ersten 25 EingriffeKlinische Monatsblätter für Augenheilkunde, 1998
- Der Intrastromale Corneale Ring (KeraVision® Ring, ICR®, ICRS®) — Eine neue, reversible Methode zur Korrektur der niedrigen Myopie Entwicklung, kritischer Vergleich mit RK und PRK, eigene refraktive Ergebnisse und Nebenwirkungen der ersten 25 EingriffeSpektrum der Augenheilkunde, 1997
- The Intrastromal Corneal Ring SegmentsOphthalmology, 1997
- lntrastromal Corneal Ring TechnologyInternational Ophthalmology Clinics, 1996
- Stromal Healing Following Explantation of an ICR (Intrastromal Corneal Ring) From a Nonfunctional Human EyeArchives of Ophthalmology (1950), 1995
- One-Year Results of the Intrastromal Corneal Ring in Nonfunctional Human EyesArchives of Ophthalmology (1950), 1995
- Flattening of central corneal curvature with Intrastromal Corneal Rings of increasing thickness: An eye-bank eye studyJournal of Cataract & Refractive Surgery, 1993
- The Intrastromal Corneal Ring: Two Cases in RabbitsJournal of Refractive Surgery, 1987