High-precision measurement of mercury isotope ratios in sediments using cold-vapor generation multi-collector inductively coupled plasma mass spectrometry
- 21 March 2006
- journal article
- research article
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 384 (7-8) , 1470-1478
- https://doi.org/10.1007/s00216-006-0373-x
Abstract
An on-line Hg reduction technique using stannous chloride as the reductant was applied for accurate and precise mercury isotope ratio determinations by multi-collector (MC)-ICP/MS. Special attention has been paid to ensure optimal conditions (such as acquisition time and mercury concentration) allowing precision measurements good enough to be able to significantly detect the anticipated small differences in Hg isotope ratios in nature. Typically, internal precision was better than 0.002% (1 RSE) on all Hg ratios investigated as long as approximately 20 ng of Hg was measured with a 10-min acquisition time. Introducing higher amounts of mercury (50 ng Hg) improved the internal precision to 205Tl/203Tl correction coupled to a standard-sample bracketing approach. The large number of data acquired allowed us to validate the consistency of our measurements over a one-year period. On average, the short-term uncertainty determined by repeated runs of NIST SRM 1641d Hg standard during a single day was 202Hg/198Hg, 202Hg/199Hg, 202Hg/200Hg, and 202Hg/201Hg). The precision fell to 202Hg/198Hg expressed as δ values (per mil deviations relative to NIST SRM 1641d Hg standard solution) displayed differences from +0.74 to −4.00‰. The magnitude of the Hg fractionation per amu was constant within one type of sample and did not exceed 1.00‰. Considering all results (the reproducibility of Hg standard solutions, reference sediment samples, and the examination of natural samples), the analytical error of our δ values for the overall method was within ±0.28‰ (1 SD), which was an order of magnitude lower than the extent of fractionation (4.74‰) observed in sediments. This study confirmed that analytical techniques have reached a level of long-term precision and accuracy that is sufficiently sensitive to detect even small differences in Hg isotope ratios that occur within one type of samples (e.g., between different sediments) and so far have unequivocally shown that Hg isotope ratios in sediments vary within approximately 5‰.Keywords
This publication has 17 references indexed in Scilit:
- High precision Hg isotope analysis of environmental samples using gold trap-MC-ICP-MSJournal of Analytical Atomic Spectrometry, 2005
- Isotope ratios on transient signals with GC–MC–ICP-MSInternational Journal of Mass Spectrometry, 2005
- Comment: Variations in the isotope composition of mercury in a freshwater sediment sequence and food webCanadian Journal of Fisheries and Aquatic Sciences, 2001
- Measurement of high precision isotope ratios for mercury from coals using transient signalsJournal of Analytical Atomic Spectrometry, 2001
- Mercury abundances and isotopic compositions in the Murchison (CM) and Allende (CV) carbonaceous chondritesGeochimica et Cosmochimica Acta, 2001
- Isotopic precision for a lead species (PbEt4) using capillary gas chromatography coupled to inductively coupled plasma-multicollector mass spectrometrySpectrochimica Acta Part B: Atomic Spectroscopy, 2001
- Variations in the isotope composition of mercury in a freshwater sediment sequence and food webCanadian Journal of Fisheries and Aquatic Sciences, 2001
- The cosmochemical behavior of mercuryEarth and Planetary Science Letters, 1999
- Applications of Multiple Collector-ICPMS to Cosmochemistry, Geochemistry, and PaleoceanographyGeochimica et Cosmochimica Acta, 1998
- Measurement of mercury isotopic ratio in stone meteorites by neutron activation analysisJournal of Radioanalytical and Nuclear Chemistry, 1997