Determining the incident electron fluence for Monte Carlo‐based photon treatment planning using a standard measured data set
- 25 March 2003
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 30 (4) , 574-582
- https://doi.org/10.1118/1.1561623
Abstract
An accurate dose calculation in phantom and patient geometries requires an accurate description of the radiation source. Errors in the radiation source description are propagated through the dose calculation. With the emergence of linear accelerators whose dosimetric characteristics are similar to within measurement uncertainty, the same radiation source description can be used as the input to dose calculation for treatment planning at many institutions with the same linear accelerator model. Our goal in the current research was to determine the initial electron fluence above the linear accelerator target for such an accelerator to allow a dose calculation in water to within 1% or 1 mm of the measured data supplied by the manufacturer. The method used for both the radiation source description and the patient transport was Monte Carlo. The linac geometry was input into the Monte Carlo code using the accelerator's manufacturer's specifications. Assumptions about the initial electron source above the target were made based on previous studies. The free parameters derived for the calculations were the mean energy and radial Gaussian width of the initial electron fluence and the target density. A combination of the free parameters yielded an initial electron fluence that, when transported through the linear accelerator and into the phantom, allowed a dose-calculation agreement to the experimental ion chamber data to within the specified criteria at both 6 and 18 MV nominal beam energies, except near the surface, particularly for the 18 MV beam. To save time during Monte Carlo treatment planning, the initial electron fluence was transported through part of the treatment head to a plane between the monitor chambers and the jaws and saved as phase-space files. These files are used for clinical Monte Carlo-based treatment planning and are freely available from the authors.Keywords
This publication has 37 references indexed in Scilit:
- Sensitivity of megavoltage photon beam Monte Carlo simulations to electron beam and other parametersMedical Physics, 2002
- Monte Carlo calculation of nine megavoltage photon beam spectra using the BEAM codeMedical Physics, 2002
- A Monte Carlo study of radiation transport through multileaf collimatorsMedical Physics, 2001
- Reference dosimetry in clinical high-energy electron beams: Comparison of the AAPM TG-51 and AAPM TG-21 dosimetry protocolsMedical Physics, 2001
- Description and dosimetric verification of the PEREGRINE Monte Carlo dose calculation system for photon beams incident on a water phantomMedical Physics, 2001
- Comparison of measured and Monte Carlo calculated dose distributions from the NRC linacMedical Physics, 2000
- Clinical implementation of a Monte Carlo treatment planning systemMedical Physics, 1999
- Uncertainties in dosimetric data and beam calibrationInternational Journal of Radiation Oncology*Biology*Physics, 1990
- Monte Carlo Simulation of Radiation Treatment Machine HeadsPublished by Springer Nature ,1988
- Compact multi-energy electron linear acceleratorsNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 1985