Abstract
The dose in the build-up region depends upon the primary photon beam, backscattered radiation from the patient and contamination radiation from outside the patient. In this paper, a model based on measured data is proposed which allows the build-up dose for arbitrarily shaped treatment fields to be determined. The dose in the build-up region is assumed to comprise a primary photon component and a contamination component that is a function of the field size and shape. This contamination component, for modelling purposes, is subdivided into contributions that correspond to elements of 1 cm by 1 cm cross-sectional area at the plane of the isocentre. The magnitude of these components has been obtained by fitting measured data to an exponential function. The exponent was found to vary linearly with depth for energies between 4 MV and 20 MV. The coefficient decreased linearly with depth at 4, 6 and 8 MV, but exhibited a broad build-up region at 20 MV. The primary component, in the build-up region, could be approximated by a function, where PSD is the primary surface dose. The values obtained during the fitting procedure were used to calculate dose in the build-up region for arbitrarily shaped fields. Good agreement was found in each case.Keywords
This publication has 27 references indexed in Scilit:
- Changes to dose in the build-up region when using multi-leaf collimators in place of lead blocks supported on an accessory trayRadiotherapy and Oncology, 1995
- Doses near the surface in high-energy x-ray beamsMedical Physics, 1995
- A Monte Carlo study of accelerator head scatterMedical Physics, 1994
- Characteristics of contamination electrons in high energy photon beamsRadiotherapy and Oncology, 1993
- On the field-size dependence of relative output from a linear acceleratorMedical Physics, 1992
- Measurement of dose in the buildup region using fixed‐separation plane‐parallel ionization chambersMedical Physics, 1990
- The polarity effect for commercially available plane‐parallel ionization chambersMedical Physics, 1987
- An investigation into the presence of secondary electrons in megavoltage photon beams (radiotherapy application)Physics in Medicine & Biology, 1983
- Electrons as the cause of the observed dmax shift with field size in high energy photon beamsMedical Physics, 1979
- The Extension of the Concept of Tissue-Air Ratios (TAR) to High-Energy X-Ray BeamsRadiology, 1970