Long-term safety of cardiac magnetic resonance imaging performed in the first few days after bare-metal stent implantation
- 1 November 2006
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 24 (5) , 1056-1061
- https://doi.org/10.1002/jmri.20740
Abstract
To investigate the long-term safety of cardiac magnetic resonance imaging (CMR) performed one to seven days after coronary artery stent (bare metal) implantation. We analyzed 119 consecutive patients with acute myocardial infarction (MI) who underwent emergency coronary stent implantation with a bare-metal stent. CMR using a 1.5T scanner was performed on 51 patients (42.9%) at a mean of 2.7+/-3.1 days after stent implantation (CMR+ group), and the remaining 68 patients (57.1%) served as controls (CMR- group). The patients were followed up to six months for major adverse cardiac events. The average stent size was 3.3+/-0.5x18.4+/-6.7 mm, and 86% of the stents were made of 316L stainless steel. There were no significant differences between the CMR+ and CMR- groups in terms of infarct features, angiographic findings, or stent characteristics. Over a mean follow-up of 4.4+/-2.1 months, 12 patients (10.1%) had 16 events (13.4%). Two patients had adverse events after early MRI scan (4.3%), a rate that is lower than the event rate in the patients who did not undergo MRI (16%, P=0.04), and one of the two events was clearly not MRI related. CMR on a 1.5T scanner can be safely performed within one to seven days after coronary bare-metal stent implantation and is not associated with an increased risk of adverse clinical cardiac outcomes. In the light of accumulating data, the guidelines by stent manufacturers should be revised.Keywords
This publication has 8 references indexed in Scilit:
- Clinical safety of magnetic resonanceimaging early after coronary artery stent placementJournal of the American College of Cardiology, 2003
- ACC/AHA Guidelines for Percutaneous Coronary Intervention (Revision of the 1993 PTCA Guidelines)—Executive SummaryCirculation, 2001
- Absence of Adverse Outcomes After Magnetic Resonance Imaging Early After Stent Placement for Acute Myocardial Infarction: A Preliminary StudyJournal of Cardiovascular Magnetic Resonance, 2000
- Coronary Arterial Stents: Safety and Artifacts during MR ImagingRadiology, 2000
- Coronary Arteries: Magnetic Resonance Imaging Seems Safe in Patients with Intracoronary StentsJournal of Cardiovascular Magnetic Resonance, 2000
- Safety of Implantable Coronary Stents During H-Magnetic Resonance Imaging at 1.0 and 1.5 TJournal of Cardiovascular Magnetic Resonance, 1999
- Behaviour of implantable coronary stents during magnetic resonance imaging.International Journal of Cardiovascular Interventions, 1999
- Absence of movement of coronary scents after placement in a magnetic resonance imaging fieldThe American Journal of Cardiology, 1994