Behaviour of implantable coronary stents during magnetic resonance imaging.
- 1 January 1999
- journal article
- research article
- Published by Taylor & Francis in International Journal of Cardiovascular Interventions
- Vol. 2 (4) , 217-222
- https://doi.org/10.1080/acc.2.4.217.222
Abstract
BACKGROUND: Magnetic resonance imaging (MRI) becomes more and more a routine diagnostic tool in clinical cardiology. In patients undergoing MRI, metallic implants may be harmful by motion or heating under certain circumstances. Many cardiac patients have implanted intracoronary stents. However, the safety of these metallic implants and especially their temperature behaviour during MRI has not been sufficiently tested. METHODS: This study investigated motion and temperature changes of 14 different stents for intracoronary application in two clinical scanners at field strengths of 1.0 and 1.5 T. At 1.5 T these studies were repeated after implantation of the stents into the coronary arteries of excised porcine hearts. Furthermore, the clinical status of 33 patients was assessed after a cardiac MR study and compared with a group of 33 patients matched for age, sex and risk factors for restenosis. RESULTS: No visible motion of the stents was observed. Furthermore, using a highly sensitive infrared camera any significant heating of the stents during MRI could be excluded. The rate of clinical events was not different in patients after MRI as compared with the control group. CONCLUSION: It is concluded that MRI is safe in patients with the currently available intracoronary stents.Keywords
This publication has 16 references indexed in Scilit:
- Calculation of electric fields induced near metal implants by magnetic resonance imaging switched-gradient magnetic fieldsMagnetic Resonance Imaging, 1997
- Effects of magnetic resonance imaging on cardiac pacemakers and electrodesAmerican Heart Journal, 1997
- Theoretical evaluation of peripheral nerve stimulation during MRI with an implanted spinal fusion stimulatorMagnetic Resonance Imaging, 1997
- Safe Performance of Magnetic Resonance Imaging on Five Patients with Permanent Cardiac PacemakersPacing and Clinical Electrophysiology, 1996
- Vascular access ports and catheters: Ex vivo testing of ferromagnetism, heating, and artifacts associated with MR imagingMagnetic Resonance Imaging, 1996
- Effects of Nuclear Magnetic Resonance Imaging on Cardiac PacemakersPacing and Clinical Electrophysiology, 1995
- Ex vivo evaluation of ferromagnetism, heating, and artifacts produced by heart valve prostheses exposed to a 1.5‐T MR systemJournal of Magnetic Resonance Imaging, 1994
- Absence of movement of coronary scents after placement in a magnetic resonance imaging fieldThe American Journal of Cardiology, 1994
- MR imaging artifacts, ferromagnetism, and magnetic torque of intravascular filters, stents, and coils.Radiology, 1988
- Magnetic resonance imaging of prosthetic heart valves.Radiology, 1985