Abstract
This study assessed the agreement between three methods of cardiac output (CO) measurement, thermodilution, the current clinical standard, and two transoesophageal echocardiographic techniques. Measurements were performed in 37 patients using thermodilution, continuous wave Doppler across the aortic valve and pulsed wave Doppler positioned in the left ventricular outflow tract. The aortic valve area was measured by direct planimetry, and the left ventricular outflow tract area was calculated from its diameter. Weighted least products regression analysis was employed to detect bias, and standard deviation of the difference (SDdiff) was calculated. There was no fixed bias but there was proportional bias between continuous wave Doppler and thermodilution methods (SDdiff 0.92 l/min). There was fixed bias but not proportional bias between pulsed wave and thermodilution methods (SDdiff 1.1 l/min). There was neither fixed nor proportional bias between pulsed wave and continuous wave Doppler methods (SDdiff 1.1 l/min). The transoesophageal Doppler methods described can be clinical alternatives to thermodilution cardiac output measurement.Keywords
This publication has 26 references indexed in Scilit:
- Intraoperative Determination of Cardiac Output Using Multiplane Transesophageal EchocardiographyAnesthesiology, 1998
- Comparison of transesophageal echocardiographic, fick, and thermodilution cardiac output in critically ill patientsJournal of Critical Care, 1996
- Pulsed Wave Doppler Measurement of Cardiac Output from the Right Ventricular Outflow TractAnesthesia & Analgesia, 1996
- Transgastric, pulsed doppler echocardiographic determination of cardiac outputIntensive Care Medicine, 1996
- Multiplane Transesophageal Echocardiographic Doppler Imaging Accurately Determines Cardiac Output Measurements in Critically III PatientsChest, 1995
- Transesophageal echocardiographic measurements of cardiac output in cardiac surgical patientsThe Annals of Thoracic Surgery, 1994
- Determination of cardiac output using acoustic quantification in critically III patientsThe American Journal of Cardiology, 1994
- Cardiac Output by Transesophageal Echocardiography Using Continuous-wave Doppler across the Aortic ValveAnesthesiology, 1994
- Comparison of Methods of Cardiac Output Measurements Determined by Dye Dilution, Pulsed Doppler Echocardiography and Thermodilution in Horses.The Journal of Veterinary Medical Science, 1994
- Intraoperative Estimation of Cardiac Output by Transesophageal Pulsed Doppler EchocardiographyAnesthesiology, 1991