Influence of Two Blood Conservation Techniques (Cardiotomy Reservoir Versus Cell-Saver) on Biocompatibility of the Heparin Coated Cardiopulmonary Bypass Circuit During Coronary Revascularization Surgery
- 1 May 1997
- journal article
- clinical trial
- Published by Hindawi Limited in Journal of Cardiac Surgery
- Vol. 12 (3) , 190-197
- https://doi.org/10.1111/j.1540-8191.1997.tb00122.x
Abstract
Blood conservation during cardiac surgery is critically important because of the inherent risks in homologous blood transfusions. Two techniques for the intraoperative conservation of blood--retransfusion of the red cells using a cell-saver (CS), or retransfusion of the blood using a cardiotomy suction (CTR) system--were compared using biocompatibility markers, granulocyte activation, and production of oxygen-free radicals (OFR). In the CTR group, heparin coated circuits with an uncoated cardiotomy reservoir were used. For the CS group, identical heparin coated cardiopulmonary bypass (CPB) sets, without a cardiotomy reservoir but with a CS, were used. In each group, eight patients had coronary artery bypass grafting performed. The capacity of the whole blood and the granulocytes to produce OFR was estimated by a chemiluminescence, and granulocyte activation was measured as release of the granulocyte granule proteins myeloperoxidase (MPO) and lactoferrin. A significantly reduced capacity to produce OFR by the whole blood was noted at 45 minutes of CPB in the CTR group (68% +/- 17% vs 94% +/- 16% in the CS group). MPO release was higher after 3 hours (p = 0.05) and 20 hours (p < 0.05), postoperatively, in the CTR group (417 +/- 77 micrograms/L and 257 +/- 31 micrograms/L vs 246 +/- 25 micrograms/L and 164 +/- 12 micrograms/L, respectively, in the CS group). We conclude that the heparin coated CPB circuit with the uncoated cardiotomy reservoir may be less biocompatible than the identical CPB set used together with the CS.Keywords
This publication has 20 references indexed in Scilit:
- Retransfusion of suctioned blood during cardiopulmonary bypass impairs hemostasisThe Annals of Thoracic Surgery, 1995
- Gegenw rtiger Stand der autologen Bluttransfusion in der Bundesrepublik DeutschlandDer Anaesthesist, 1995
- Intraoperative autologous blood salvage with cardiac surgery: An analysis of five years' experience in more than 3,000 patientsJournal of Clinical Anesthesia, 1992
- Decreased Blood Loss After Cardiopulmonary Bypass using Heparin-Coated Circuit and 50% Reduction of Heparin DoseScandinavian Journal of Thoracic and Cardiovascular Surgery, 1992
- Blood salvage in cardiac surgeryJournal of Cardiothoracic and Vascular Anesthesia, 1991
- The variability of transfusion practice in coronary artery bypass surgery. Transfusion Medicine Academic Award GroupPublished by American Medical Association (AMA) ,1991
- Inflammatory Response Due to Cell-Saver in Cardiac SurgeryPublished by Springer Nature ,1991
- Blood Cell Trauma and Postoperative Bleeding: Comparison of Bubble and Membrane Oxygenators and Observations on Coronary SuctionScandinavian Journal of Thoracic and Cardiovascular Surgery, 1990
- Chemiluminescence of whole bloodClinical Immunology and Immunopathology, 1983
- A New Non-Thrombogenic Surface Prepared by Selective Covalent Binding of Heparin Via a Modified Reducing Terminal ResidueBiomaterials, Medical Devices, and Artificial Organs, 1983