The Validity of Performance Assessments Using Simulation
- 1 July 2001
- journal article
- research article
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 95 (1) , 36-42
- https://doi.org/10.1097/00000542-200107000-00011
Abstract
Background: The authors wished to determine whether a simulator-based evaluation technique assessing clinical performance could demonstrate construct validity and determine the subjects' perception of realism of the evaluation process. Methods: Research ethics board approval and informed consent were obtained. Subjects were 33 university-based anesthesiologists, 46 community-based anesthesiologists, 23 final-year anesthesiology residents, and 37 final-year medical students. The simulation involved patient evaluation, induction, and maintenance of anesthesia. Each problem was scored as follows: no response to the problem, score = 0; compensating intervention, score = 1; and corrective treatment, score = 2. Examples of problems included atelectasis, coronary ischemia, and hypothermia. After the simulation, participants rated the realism of their experience on a 10-point visual analog scale (VAS). Results: After testing for internal consistency, a seven-item scenario remained. The mean proportion scoring correct answers (out of 7) for each group was as follows: university-based anesthesiologists = 0.53, community-based anesthesiologists = 0.38, residents = 0.54, and medical students = 0.15. The overall group differences were significant (P < 0.0001). The overall realism VAS score was 7.8. There was no relation between the simulator score and the realism VAS (R = -0.07, P = 0.41). Conclusions: The simulation-based evaluation method was able to discriminate between practice categories, demonstrating construct validity. Subjects rated the realism of the test scenario highly, suggesting that familiarity or comfort with the simulation environment had little or no effect on performance.Keywords
This publication has 10 references indexed in Scilit:
- Assessment of Clinical Performance during Simulated Crises Using Both Technical and Behavioral RatingsAnesthesiology, 1998
- Patient Simulator Competency TestingAnesthesia & Analgesia, 1998
- Testing Internal Consistency and Construct Validity During Evaluation of Performance in a Patient SimulatorAnesthesia & Analgesia, 1998
- Response to atracurium and mivacurium in a patient with Charcot-Marie-Tooth diseaseCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 1998
- The cost for construction and operation of a simulation centreCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 1997
- Testing the raters: inter-rater reliability of standardized anaesthesia simulator performanceCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 1997
- Responses to simulated anaesthetic emergencies by anaesthetists with different durations of clinical experienceBritish Journal of Anaesthesia, 1997
- The oral examination in anaesthetic resident evaluationCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 1993
- The Canadian four-centre study of anaesthetic outcomes: II. Can outcomes be used to assess the quality of anaesthesia care?Canadian Journal of Anesthesia/Journal canadien d'anesthésie, 1992