Non‐conventional uses of the Aintree Intubating Catheter in management of the difficult airway
- 10 January 2007
- journal article
- case report
- Published by Wiley in Anaesthesia
- Vol. 62 (2) , 169-174
- https://doi.org/10.1111/j.1365-2044.2006.04909.x
Abstract
We present 14 cases, of which three have been previously reported, in which non-conventional use was made of the Aintree Intubating Catheter (AIC). In seven cases the AIC was used via a ProSeal Laryngeal mask airway (PLMA). Two patients had anticipated difficult intubation, two unexpected difficult intubation and two required rescue of an obstructed airway prior to AIC-assisted intubation. In two cases of tracheal stenosis the AIC was used as a 'long narrow tracheal tube' during fibre-optic intubation: the AIC facilitated passage through the narrowed trachea and smooth railroading of a tracheal tube. In two cases the AIC was used in an awake patient. In three cases the AIC was used successfully despite gross laryngeal oedema. In three cases attempted AIC deployment failed: two patients had undergone radiotherapy to the mouth and PLMA placement failed; in the third, supraglottic oedema prevented visualisation of the larynx. The AIC via an LMA Classic was successful in one of these cases. In all cases where the larynx was visualised the AIC was rapidly successful without complications. In eight cases the anaesthetist had no experience of the technique outside workshops. These cases demonstrate general utility of the technique and successful use of the AIC via the PLMA, in awake patients, as an adjunct to fibre-optic intubation and in patients with an oedematous larynx. Finally, cases where the combination of the PLMA and AIC was unsuccessful demonstrate the technique, like many, is not always successful.Keywords
This publication has 16 references indexed in Scilit:
- Tracheal intubation via the Classic™ and Proseal™ laryngeal mask airways: a manikin study using the Aintree Intubating CatheterAnaesthesia, 2007
- A complication of transtracheal jet ventilation and use of the Aintree intubation catheter® during airway resuscitationAnaesthesia, 2006
- A response to 'Low-skill fibreoptic intubation: use of the Aintree Catheter with the classic LMA'Anaesthesia, 2006
- Airway rescue in acute upper airway obstruction using a ProSeal™ Laryngeal mask airway and an Aintree Catheter™: a review of the ProSeal™ Laryngeal mask airway in the management of the difficult airwayAnaesthesia, 2005
- The proseal™laryngeal mask airway: a review of the literatureCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 2005
- Low‐skill fibreoptic intubation: use of the Aintree Catheter with the classic LMAAnaesthesia, 2005
- La sédation au propofol permet l’intubation difficile vigile avec le masque laryngé FastrachTMCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 2005
- Use of the Pro-Seal LMA facilitates percutaneous dilatational tracheostomyCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 2003
- A clinical sign to predict difficult tracheal intubation; a prospective studyCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 1985
- Difficult tracheal intubation in obstetricsAnaesthesia, 1984