Estimating effective dose for a cardiac catheterisation procedure with single or double personal dosemeters
- 3 March 2006
- journal article
- research article
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 118 (2) , 196-204
- https://doi.org/10.1093/rpd/ncl018
Abstract
In most countries of the European Union legislation requires individual determination and registration of the dose to radiological workers exposed to ionising radiation to check whether dose limits are exceeded. To assess stochastic risk, ideally effective dose (E) should be known. In practice, personal dose equivalent [HP(10)] is used as it can be measured with a personal dosemeter. The dosemeter reading may provide a reasonable assessment of HP(10), but it may deviate strongly from E, in particular in radiology procedures for medical diagnosis or intervention when protective clothing like lead-equivalent apron and thyroid collar is worn. In the literature various correction factors and algorithms to convert readings of single or dual dosemeters to an estimate of E can be found. An illustrative example of a cardiac catheterisation procedure, in which dose calculations are made by Monte Carlo simulation of radiation transport, shows that such corrections may still yield considerable overestimation.Keywords
This publication has 11 references indexed in Scilit:
- A catalogue of dosemeters and dosimetric services within Europe--an updateRadiation Protection Dosimetry, 2004
- Occupational dose constraints in interventional cardiology procedures: the DIMOND approachPhysics in Medicine & Biology, 2004
- Monte Carlo calculations for assessment of radiation dose to patients with congenital heart defects and to staff during cardiac catheterizationsThe British Journal of Radiology, 2003
- Relationship between protection and operational quantities in dosimetry of photon external exposure - deficiencies of Hp(10)Radiation Protection Dosimetry, 2003
- Staff Dosimetry Protocols in Interventional RadiologyRadiation Protection Dosimetry, 2001
- Modifications to the ORNL Phantom Series in Simulation of the Responses of Thyroid DetectorsRadiation Protection Dosimetry, 1998
- Effectiveness of lead aprons in vascular radiology: results of clinical measurements.Radiology, 1995
- The Estimation of Occupational Effective Dose in Diagnostic Radiology With Two DosimetersHealth Physics, 1994
- Guidance on personal dosimetry for occupational exposure in interventional radiologyJournal of Radiological Protection, 1994
- The Relationship of Effective Dose to Personnel and Monitor Reading for Simulated Fluoroscopic Irradiation ConditionsHealth Physics, 1993