Computer-controlledin vitro model of the human left heart
- 1 November 1992
- journal article
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 30 (6) , 656-659
- https://doi.org/10.1007/bf02446800
Abstract
The decision for surgical intervention in the treatment of stenosis and for regurgitation of the mitral valve demands an objective and quantitative evaluation of the severity of mitral valve disease. The availability of ultrasound techniques capable of analysing flow velocities across valves and to produce representative images of valve orifices has increased the interest in the hydraulics of cardiac valves. To isolate and study the determinants of transmitral flow, an in vitro model of the human left heart was built. From the model it is possible to differentiate the influence of the different determinants of left heart performance on transmitral flow: preload, compliance of the left atrium and ventricle, peripheral resistance (afterload) and heart rate. The mechanical part of the model consists of a reservoir connected to an elastic closed circuit (Latex pulmonary veins, left atrium, left ventricle and aortic arch) with replaceable mitral and aortic valves. The electronic part of the model drives and controls the hydraulic part, allowing the independent regulation and monitoring of left atrial and left ventricular pressures p, volumes V and 'pV-loops' throughout the cardiac cycle at different cardiac rhythms. Left atrial filling pressure and aortic resistance are variable in a controlled fashion. Echo-Doppler study of the mitral valve and the transmitral valve flow is possible both from an atrial and a ventricular window in the model. This technical note describes the model.Keywords
This publication has 11 references indexed in Scilit:
- A new method for noninvasive quantification of valvular regurgitation based on conservation of momentum. In vitro validation.Circulation, 1989
- Fluid dynamics model of mitral valve flow: Description with in vitro validationJournal of the American College of Cardiology, 1989
- In vitro comparison of aortic heart valve prosthesesThe Journal of Thoracic and Cardiovascular Surgery, 1988
- INVITRO COMPARISON OF AORTIC HEART-VALVE PROSTHESES .1. MECHANICAL VALVES1988
- In Vitro Evaluation of Six Mechanical and Six Bioprosthetic ValvesThe Thoracic and Cardiovascular Surgeon, 1986
- Bileaflet, tilting disc and porcine aortic valve substitutes: In vitro hydrodynamic characteristicsJournal of the American College of Cardiology, 1984
- NEW GENERATION TISSUE VALVES - THEIR INVITRO FUNCTION IN THE MITRAL POSITION1984
- A fluid-mechanical study of the closure of heart valvesJournal of Fluid Mechanics, 1979
- In vitro hydrodynamic comparison of mitral valve prostheses at high flow ratesThe Journal of Thoracic and Cardiovascular Surgery, 1978