Abstract
The maximum electric field intensity (E) in field asymmetric waveform ion mobility spectrometry (FAIMS) analyses was doubled to E > 60 kV/cm. In earlier devices with >0.5 mm gaps, such strong fields cause electrical breakdown for nearly all gases at ambient pressure. As the Paschen curves are sublinear, thinner gaps permit higher E: here, we established 61 kV/cm in N2 using microchips with 35 μm gaps. As FAIMS efficiency is exceptionally sensitive to E, such values can in theory accelerate analyses at equal resolution by over an order of magnitude. Here we demonstrate FAIMS filtering in ∼20 μs or ∼1% of the previously needed time, with a resolving power of about half that for “macroscopic” units but sufficing for many applications. Microscopic gaps enable concurrent ion processing in multiple (here, 47) channels, which greatly relaxes the charge capacity constraints of planar FAIMS designs. These chips were integrated with a β-radiation ion source and charge detector. The separation performance is in line with first-principles modeling that accounts for high-field and anisotropic ion diffusion. By extending FAIMS operation into the previously inaccessible field range, the present instrument advances the capabilities for research into ion transport and expands options for separation of hard-to-resolve species.This publication has 47 references indexed in Scilit:
- Pendular proteins in gases and new avenues for characterization of macromolecules by ion mobility spectrometryProceedings of the National Academy of Sciences, 2009
- Optimum waveforms for differential ion mobility spectrometry (FAIMS)Published by American Chemical Society (ACS) ,2008
- Control of Ion Distortion in Field Asymmetric Waveform Ion Mobility Spectrometry via Variation of Dispersion Field and Gas TemperatureAnalytical Chemistry, 2008
- Assessing the Dynamic Range and Peak Capacity of Nanoflow LC−FAIMS−MS on an Ion Trap Mass Spectrometer for ProteomicsAnalytical Chemistry, 2008
- Ion mobility spectrometry—mass spectrometry performance using electrodynamic ion funnels and elevated drift gas pressuresPublished by American Chemical Society (ACS) ,2007
- High-Resolution Field Asymmetric Waveform Ion Mobility Spectrometry Using New Planar Geometry AnalyzersAnalytical Chemistry, 2006
- Feasibility of Higher-Order Differential Ion Mobility Separations Using New Asymmetric WaveformsThe Journal of Physical Chemistry A, 2006
- High-field asymmetric waveform ion mobility spectrometry: A new tool for mass spectrometryJournal of Chromatography A, 2004
- Qualitative analysis of trace constituents by ion mobility increment spectrometerTalanta, 2003
- Determination of Parts-per-Trillion Levels of Chlorate, Bromate, and Iodate by Electrospray Ionization/High-Field Asymmetric Waveform Ion Mobility Spectrometry/Mass SpectrometryApplied Spectroscopy, 1999