Characterization of Signal Properties in Atherosclerotic Plaque Components by Intravascular MRI
- 1 July 2000
- journal article
- other
- Published by Wolters Kluwer Health in Arteriosclerosis, Thrombosis, and Vascular Biology
- Vol. 20 (7) , 1824-1830
- https://doi.org/10.1161/01.atv.20.7.1824
Abstract
—Magnetic resonance imaging (MRI) is capable of distinguishing between atherosclerotic plaque components solely on the basis of biochemical differences. However, to date, the majority of plaque characterization has been performed by using high-field strength units or special coils, which are not clinically applicable. Thus, the purpose of the present study was to evaluate MRI properties in histologically verified plaque components in excised human carotid endarterectomy specimens with the use of a 5F catheter–based imaging coil, standard acquisition software, and a clinical scanner operating at 0.5 T. Human carotid endarterectomy specimens from 17 patients were imaged at 37°C by use of an opposed solenoid intravascular radiofrequency coil integrated into a 5F double-lumen catheter interfaced to a 0.5-T General Electric interventional scanner. Cross-sectional intravascular MRI (156×250 μm in-plane resolution) that used different imaging parameters permitted the calculation of absolute T1and T2, the magnetization transfer contrast ratio, the magnitude of regional signal loss associated with an inversion recovery sequence (inversion ratio), and regional signal loss in gradient echo (gradient echo–to–spin echo ratio) in plaque components. Histological staining included hematoxylin and eosin, Masson’s trichrome, Kossa, oil red O, and Gomori’s iron stain. X-ray micrographs were also used to identify regions of calcium. Seven plaque components were evaluated: fibrous cap, smooth muscle cells, organizing thrombus, fresh thrombus, lipid, edema, and calcium. The magnetization transfer contrast ratio was significantly less in the fibrous cap (0.62±13) than in all other components ( P P P <0.04). Absolute T1 (range 300±140 ms for lipid to 630±321 ms for calcium) and T2 (range 40±12 ms for fresh thrombus to 59±21 ms for smooth muscle cells) were not significantly different between groups. In vitro intravascular MRI with catheter-based coils and standard software permits sufficient spatial resolution to visualize major plaque components. Pulse sequences that take advantage of differences in biochemical structure of individual plaque components show quantitative differences in signal properties between fibrous cap, lipid, and calcium. Therefore, catheter-based imaging coils may have the potential to identify and characterize those intraplaque components associated with plaque stability by use of existing whole-body scanners.Keywords
This publication has 18 references indexed in Scilit:
- A rapid 2D time‐resolved variable‐rate k‐space sampling MR technique for passive catheter tracking during endovascular proceduresMagnetic Resonance in Medicine, 1998
- Intravascular magnetic resonance imaging using a loopless catheter antennaMagnetic Resonance in Medicine, 1997
- High resolution intravascular MRI and MRS by using a catheter receiver coilMagnetic Resonance in Medicine, 1996
- Calcification Can Shorten T2, but not Tl, at Magnetic Resonance Imaging FieldsInvestigative Radiology, 1995
- On MR imaging of atheromatous lipids in human arteriesJournal of Magnetic Resonance Imaging, 1995
- High expression of genes for calcification-regulating proteins in human atherosclerotic plaques.Journal of Clinical Investigation, 1994
- Characterization of the relative thrombogenicity of atherosclerotic plaque components: Implications for consequences of plaque ruptureJournal of the American College of Cardiology, 1994
- Nuclear Magnetic Resonance Microscopy of Atheroma in Human Coronary ArteriesAngiology, 1991
- Chemical Shift Imaging of Atherosclerosis at 7.0 TeslaInvestigative Radiology, 1989
- High‐resolution H NMR spectral signature from human atheromaMagnetic Resonance in Medicine, 1988