Use of dual-energy X-ray absorptiometry in obese individuals
Open Access
- 1 October 1995
- journal article
- research article
- Published by Elsevier in The American Journal of Clinical Nutrition
- Vol. 62 (4) , 730-734
- https://doi.org/10.1093/ajcn/62.4.730
Abstract
Dual-energy X-ray absorptiometry (DXA) provides precise measurements of body composition in humans. Because its use in obese subjects is limited by the size of the scanning area, we explored the possibility of estimating whole-body composition from DXA half-body scans. Body composition of 183 subjects with a wide range of body sizes [body mass index (BMI; in kg/m2) of 17.7 - 52.8] was assessed by DXA and hydrodensitometry. Subjects fitting in the DXA scanning area (group A, n = 156) were scanned once whereas subjects exceeding it (group B, n = 27) were scanned twice, once for each side of the body. When body-composition results for the right and left sides were compared, only minimal differences between the two sides of the body were found in both groups. Least-squares-regression analysis of whole-body composition by hydrodensitometry on DXA gave the following results: percent body fat, r2 = 0.89 (SEE = 4.1%); fat-free mass, r2 = 0.89 (SEE = 3.72 kg); and fat mass, r2 = 0.95 (SEE = 3.57 kg). Similar r2 values and SEEs were obtained for percent body fat when only results from DXA half-body scans of all subjects were considered: right side, r2 = 0.90 (SEE = 4.1%); and left side, r2 = 0.89 (SEE = 4.2%). The error in predicting body composition by hydrodensitometry from DXA whole- or half-body scans was not affected by the subject's body size and/or scanning technique. In conclusion, our results indicate that half-body scan values by DXA accurately predict whole-body composition.Keywords
This publication has 12 references indexed in Scilit:
- Accuracy of dual-energy x-ray absorptiometry for body-composition measurements in childrenThe American Journal of Clinical Nutrition, 1994
- Use of dual-energy x-ray absorptiometry in body-composition studies: not yet a “gold standard”The American Journal of Clinical Nutrition, 1993
- Accuracy of measurements of body composition by dual-energy x-ray absorptiometry in vivoThe American Journal of Clinical Nutrition, 1993
- Determination of body composition—a comparison of dual-energy x-ray absorptiometry and hydrodensitometryThe American Journal of Clinical Nutrition, 1993
- Total body absorptiometry in postmenopausal osteoporosis patients treated with lα-hydroxylated vitamin D metabolitesOsteoporosis International, 1993
- Sex- and menopause-associated changes in body-fat distributionThe American Journal of Clinical Nutrition, 1992
- Evaluation of a new set of calibration standards for the measurement of fat content via DPA and DXAMedical Physics, 1992
- Validation of body composition by dual energy X‐ray absorptiometry (DEXA)Clinical Physiology and Functional Imaging, 1991
- Comparison of dual-photon absorptiometry systems for total-body bone and soft tissue measurements: Dual-energy X-rays versus gadolinium 153Journal of Bone and Mineral Research, 1991
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986