Depth dose and off-axis characteristics of TLD in therapeutic pion beams
- 1 July 1980
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 25 (4) , 667-676
- https://doi.org/10.1088/0031-9155/25/4/005
Abstract
The thermoluminescent (TL) response of LiF (TLD-100, TLD-600, TLD-700) and Li2B4O7 (TLD-800) has been measured as a function of depth and off-axis position in a therapeutic negative-pion beam in order to evaluate their usefulness in pion radiotherapy. TLD-100, TLD-600, and TLD-800 have been shown to be of little use as in vivo dosemeters because the neutron kerma relative to that in tissue changes grossly with depth. The neutron source comes primarily from pion absorption in the lead-alloy collimator. The 200 degrees C TLD-700 response agrees well with the depth dose spectra, except for small changes due to the varying linear energy transfer (LET) distributions. This variation can be partially accounted for by incorporating the known LET response of LiF. The 260 degrees C peak of TLD-700 has been found to be approximately four times more sensitive than the 200 degrees C peak to high LET dose. Using a simple model of the LET responses, the measured 200 degrees C and 260 degrees C peaks predict total dose within +or-4% and high LET dose within +or-50%, therefore indicating TLD-700 to be a good in vivo dosemeter for total dose but only an indicator of high LET dose.This publication has 12 references indexed in Scilit:
- Thermoluminescent response of LiF and Li2B4O7:Mn to pionsPhysics in Medicine & Biology, 1980
- Static pion beam treatment planning of deep seated tumors using computerized tomographic scansInternational Journal of Radiation Oncology*Biology*Physics, 1979
- Studies of the effect of LET on the thermoluminescent properties of thin lithium fluoride layersPhysics in Medicine & Biology, 1978
- Response of multicellular tumor spheroids to multiple fractions of negative PI-mesons and X-raysInternational Journal of Radiation Oncology*Biology*Physics, 1977
- In-vivo dosimetry for negative pion therapyInternational Journal of Radiation Oncology*Biology*Physics, 1977
- Use of a dynamic rangeshifter for modifying the depth‐dose distributions of negative pionsMedical Physics, 1977
- Revised energy responses of 6LiF and 7LiF thermoluminescence dosimeters to neutronsNuclear Instruments and Methods, 1977
- Response of 6LiF and 7LiF thermoluminescence dosimeters to fast neutronsNuclear Instruments and Methods, 1972
- The absorption of negative pions by complex nuclei (copper, tin and lead)Il Nuovo Cimento (1869-1876), 1964
- Energy Spectra of Neutrons Emitted FollowingCapture in C, A1, Cd, Pb, and UPhysical Review B, 1964