High-Throughput Quantification of Drugs and Their Metabolites in Biosamples by LC-MS/MS and CE-MS/MS: Possibilities and Limitations
- 1 February 2002
- journal article
- research article
- Published by Wolters Kluwer Health in Therapeutic Drug Monitoring
- Vol. 24 (1) , 134-143
- https://doi.org/10.1097/00007691-200202000-00021
Abstract
Off-line solid phase extraction with C18 disk plates and turbulent flow chromatography were evaluated versus on-line solid phase extraction using column-switching HPLC as sample preparation techniques for high-throughput analysis of pharmaceutical compounds and their metabolites by LC-MS/MS. Turbulent flow chromatography was found to be very straightforward in its applicaton, but the LOQs were more than fivefold higher compared with off-line or other on-line solid phase extraction methods. Solid phase extraction (SPE) on disk was found to be fast and sufficient efficient to minimize matrix effects and therefore an apprach to provide sensitive and reliable LC-MS/MS methods. Column-switching HPLC with microbore columns (0.5 mm i.d.) were used for fast analysis of a parent drug and four of its metabolites utilizing steep gradients in 1 minute. The application of CZE-MS/MS for bionalysis of pharamaceutical compounds is also discussed.Keywords
This publication has 18 references indexed in Scilit:
- Multiple‐sprayer tandem mass spectrometry with parallel high flow extraction and parallel separation for high‐throughput quantitation in biological fluidsRapid Communications in Mass Spectrometry, 2001
- High‐speed liquid chromatography/tandem mass spectrometry using a monolithic column for high‐throughput bioanalysisRapid Communications in Mass Spectrometry, 2001
- Evaluation of a Four-Channel Multiplexed Electrospray Triple Quadrupole Mass Spectrometer for the Simultaneous Validation of LC/MS/MS Methods in Four Different Preclinical MatrixesAnalytical Chemistry, 2001
- A Four-Column Parallel Chromatography System for Isocratic or Gradient LC/MS AnalysesAnalytical Chemistry, 2001
- A clinical trial on a plate? The potential of 384-well format solid phase extraction for high-throughput bioanalysis using liquid chromatography/tandem mass spectrometryRapid Communications in Mass Spectrometry, 2000
- Parallel ultra-high flow rate liquid chromatography with mass spectrometric detection using a multiplex electrospray source for direct, sensitive determination of pharmaceuticals in plasma at extremely high throughputRapid Communications in Mass Spectrometry, 2000
- Bioanalytical High-Throughput Selected Reaction Monitoring-LC/MS Determination of Selected Estrogen Receptor Modulators in Human Plasma: 2000 Samples/DayAnalytical Chemistry, 2000
- Demonstration of the capabilities of a parallel high performance liquid chromatography tandem mass spectrometry system for use in the analysis of drug discovery plasma samplesRapid Communications in Mass Spectrometry, 1999
- Ultra-high flow rate capillary liquid chromatography with mass spectrometric detection for the direct analysis of pharmaceuticals in plasma at sub-nanogram per millilitre concentrationsRapid Communications in Mass Spectrometry, 1999
- The effects of sample preparation methods on the variability of the electrospray ionization response for model drug compoundsRapid Communications in Mass Spectrometry, 1999