Use of a quadrupole linear ion trap mass spectrometer in metabolite identification and bioanalysis
Open Access
- 16 April 2003
- journal article
- research article
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 17 (11) , 1137-1145
- https://doi.org/10.1002/rcm.1037
Abstract
A new type of quadrupole linear ion trap mass spectrometer, Q TRAP™ LC/MS/MS system (Q TRAP™), was evaluated for its performance in two studies: firstly, the in vitro metabolism of gemfibrozil in human liver microsomes, and, secondly, the quantification of propranolol in rat plasma. With the built‐in information‐dependent‐acquisition (IDA) software, the instrument utilizes full scan MS in the ion trap mode and/or constant neutral loss scans as survey scans to trigger product ion scan (MS2) and MS3 experiments to obtain structural information of drug metabolites ‘on‐the‐fly’. Using this approach, five metabolites of gemfibrozil were detected in a single injection. This instrument combines some of the unique features of a triple quadrupole mass spectrometer, such as constant neutral loss scan, precursor ion scan and multiple reaction monitoring (MRM), together with the capability of a three‐dimensional ion trap. Therefore, it becomes a powerful instrument for metabolite identification. The fast duty cycle in the ion trap mode allows the use of full product ion scan for quantification. For the quantification of propranolol, both MRM mode and full product ion scan in the ion trap mode were employed. Similar sensitivity, reproducibility and linearity values were established using these two approaches. The use of the product ion scan mode for quantification provided a convenient tool in selecting transitions for improving selectivity during the method development stage. Copyright © 2003 John Wiley & Sons, Ltd.Keywords
This publication has 18 references indexed in Scilit:
- Comparison in patients with type 2 diabetes of fibric acid versus hepatic hydroxymethyl glutaryl-coenzyme a reductase inhibitor treatment of combined dyslipidemia.Metabolism, 2002
- Use of a liquid chromatography/ion trap mass spectrometry/triple quadrupole mass spectrometry system for metabolite identificationRapid Communications in Mass Spectrometry, 2002
- A two-dimensional quadrupole ion trap mass spectrometerPublished by American Chemical Society (ACS) ,2002
- A new linear ion trap mass spectrometerRapid Communications in Mass Spectrometry, 2002
- A combined linear ion trap time‐of‐flight system with improved performance and MSn capabilitiesRapid Communications in Mass Spectrometry, 2001
- Chemical Image Fusion. The Synergy of FT-NIR and Raman Mapping Microscopy To Enable a More Complete Visualization of Pharmaceutical FormulationsAnalytical Chemistry, 2001
- Characterization of an electrospray ionization ion trap/linear time-of-flight mass spectrometer for phenylthiohydantoin-amino acid analysisInternational Journal of Mass Spectrometry, 1998
- Drug Therapy of MigraineNew England Journal of Medicine, 1993
- Book Review The Airway: Emergency Management Edited by Robert H. Dailey, Barry Simon, Gary P. Young, and Ronald D. Stewart. 397 pp., illustrated. St. Louis, Mosby-Year Book, 1992. $62. 0-8016-1270-5New England Journal of Medicine, 1993
- Tandem mass spectrometry (MS/MS) instrumentationMass Spectrometry Reviews, 1983