Experimental evaluation of the Dideco D903 Avant 1.7 hollow-fibre membrane oxygenator
- 1 September 1998
- journal article
- research article
- Published by SAGE Publications in Perfusion
- Vol. 13 (5) , 353-359
- https://doi.org/10.1177/026765919801300512
Abstract
Membrane oxygenators have now gained wide acceptance. A new hollow-fibre membrane oxygenator, the Dideco D903 Avant 1.7, with an optimized membrane surface (1.7 m2) and a wavy blood flow pattern, was tested for gas transfer and blood path resistance in a standardized setting with surviving animals. Three calves (mean body weight 63.29 ± 2.9 kg) were connected to cardiopulmonary bypass by jugular venous and carotid arterial cannulation, classic roller pump and the Dideco D903 oxygenator with a mean flow rate of 53 ± 0.1 ml/kg/min for 6 h. After this time, the animals were weaned from the CPB and thereafter from the ventilator. After 7 days, the animals were killed electively. Blood gas analysis was performed before bypass, after mixing (10 min) and then hourly for the 6 h of perfusion. Further samples were taken 30 min (spontaneous breathing) and 60 min after bypass (extubated). Physiological blood gas values could be maintained throughout perfusion in all animals. Mean arterial oxygen saturation varied between 99.3% and 99.7% for the arterial side of the oxygenator compared to 64.6% and 71% for the venous side. The highest mean pressure drop through the oxygenator was 54 mmHg. Postbypass blood gas analysis showed physiological values and no evidence of major lung trauma or pulmonary oedema in relation to the 6 h perfusion. The hollow-fibre membrane oxygenator, Dideco D903, offers excellent gas exchange capabilities and a low pressure drop under experimental conditions, despite reduced membrane surface area. The post mortem examination did not show any deleterious lesion.Keywords
This publication has 10 references indexed in Scilit:
- Comparison of the performance characteristics of three generations of membrane oxygenators: Univox®, Univox® Gold™ and SpiralGold™Perfusion, 1996
- Membrane oxygenators: influence of design on performancePerfusion, 1994
- Improved Biocompatibility of Heparin Surface-Coated Ventricular Assist DevicesThe International Journal of Artificial Organs, 1992
- Blood - Artificial Surface Interactions during Cardiopulmonary BypassThe International Journal of Artificial Organs, 1990
- Blood Cell Trauma and Postoperative Bleeding: Comparison of Bubble and Membrane Oxygenators and Observations on Coronary SuctionScandinavian Journal of Thoracic and Cardiovascular Surgery, 1990
- Bubble and Membrane Oxygenators—Comparison of Postoperative Organ Dysfunction with Special Reference to Inflammatory ActivityScandinavian Journal of Thoracic and Cardiovascular Surgery, 1990
- Experimental evaluation of the Dideco Masterflo paediatric hollow-fibre membrane oxygenatorPerfusion, 1989
- Determination of significant differences in performance of the Bentley BOS-CM 40 hollow fibre membrane oxygenator and the Polystan VT5000 venotherm bubble oxygenatorPerfusion, 1987
- Comparison of bubble and membrane oxygenators in short and long perfusionsThe Journal of Thoracic and Cardiovascular Surgery, 1979