Method for MRI-guided conformal thermal therapy of prostate with planar transurethral ultrasound heating applicators
- 12 October 2005
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 50 (21) , 4957-4975
- https://doi.org/10.1088/0031-9155/50/21/001
Abstract
A method for conformal prostate thermal therapy using transurethral ultrasound heating applicators incorporating planar transducers is described. The capability to shape heating patterns to the geometry of the prostate gland from a single element in a multi-element heating applicator was evaluated using Bioheat transfer modelling. Eleven prostate geometries were obtained from patients who underwent MR imaging of the prostate gland prior to radical prostatectomy. Results indicate that ultrasound heating applicators incorporating multi-frequency planar transducers (4 x 20 mm, f = 4.7 MHz, 9.7 MHz) are capable of shaping thermal damage patterns to the geometry of individual prostates. A temperature feedback control algorithm has been developed to control the frequency, rotation rate and applied power level from transurethral heating applicators based on measurements of the boundary temperature during heating. The discrepancy between the thermal damage boundary and the target boundary was less than 5 mm, and the transition distance between coagulation and normal tissue was less than 1 cm. Treatment times for large prostate volumes were less than 50 min, and perfusion did not have significant impact on the control algorithm. Rectal cooling will play an important role in reducing undesired heating near the rectal wall. Experimental validation of the simulations in a tissue-mimicking gel phantom demonstrated good agreement between the predicted and generated patterns of thermal damage.Keywords
This publication has 41 references indexed in Scilit:
- Catheter-based ultrasound applicators for selective thermal ablation: progress towards MRI-guided applications in prostateInternational Journal of Hyperthermia, 2004
- Transurethral ultrasound applicators with directional heating patterns for prostate thermal therapy:In vivoevaluation using magnetic resonance thermometryMedical Physics, 2004
- Multifrequency ultrasound transducers for conformal interstitial thermal therapyIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2003
- Basic principles of thermal dosimetry and thermal thresholds for tissue damage from hyperthermiaInternational Journal of Hyperthermia, 2003
- Interstitial ultrasound heating applicator for MR-guided thermal therapy.Physics in Medicine & Biology, 2001
- Transrectal High-Intensity Focused Ultrasound: Minimally Invasive Therapy of Localized Prostate CancerJournal of Endourology, 2000
- Feasibility of linear arrays for interstitial ultrasound thermal therapyMedical Physics, 2000
- Combination of transurethral and interstitial ultrasound applicators for high-temperature prostate thermal therapyInternational Journal of Hyperthermia, 2000
- Fast lipid-suppressed MR temperature mapping with echo-shifted gradient-echo imaging and spectral-spatial excitationMagnetic Resonance in Medicine, 1999
- Quantifying tissue damage due to focused ultrasound heating observed by MRIMagnetic Resonance in Medicine, 1999