Immunologic differentiation of absolute lymphocyte count with an integrated flow cytometric system: A new concept for absolute T cell subset determinations
- 15 March 1995
- Vol. 22 (1) , 48-59
- https://doi.org/10.1002/cyto.990220110
Abstract
We describe a method to obtain results for immune status monitoring that uses a three‐test panel, comprised of isotype control and 2 specific Mab tests (CD4/CD8/CD3 and CD16/CD19/CD3), in conjunction with a flow cytometer that directly measures absolute counts. Automated software is used for lineagespecific gating of three‐color immunofluorescence to determine lymphocyte and lymphocyte subset counts. The autogating function of this software is shown to yield equivalent results to manual analysis by an expert user, and to be effective when as few as 25 target cells are present. The software is also shown to perform automatic quality control checks of the sample preparation, reagent, and automated analysis. We demonstrate that the sum of T (CD3 +), B (CD19 +), and natural killer (NK, CD16 + CD3−) cells, as a determination of all lymphocytes, correlates well with lymphocytes measured using a light scatter differential. Moreover, T + B + NK lymphocyte count is shown to be less error‐prone than lymphocyte count from light scatter differential, and to minimize errors that arise from between‐technician variation in sample preparation. Our data suggest that the new approach that we describe could offer an alternative to the traditional two‐stage methods for measuring absolute counts of lymphocyte subsets for immune status monitoring. As such this method could reduce, through objective automated analysis, testing cost and complexity, without sacrificing the quality of results.Keywords
This publication has 23 references indexed in Scilit:
- Light scatter based lymphocyte gate–helpful tool or source of error?Cytometry, 1994
- The novel subset of CD14+/CD16+ blood monocytes exhibits features of tissue macrophagesEuropean Journal of Immunology, 1993
- CD4 T‐lymphocyte determinations on whole blood specimens using a single‐tube three‐color assayCytometry, 1993
- A Novel Dye That Facilitates Three‐Color Analysis of PBMC by Flow CytometryAnnals of the New York Academy of Sciences, 1993
- Flow cytometric evaluation of human basophilsCytometry, 1993
- Heterogeneity of peripheral blood monocyte populations in human immunodeficiency virus-1 seropositive patientsFEMS Microbiology Letters, 1992
- Effect of type of haematology analyser on CD4 countThe Lancet, 1992
- Lack of leu‐3a epitope on t‐helper (cd4) lymphocytesJournal of Clinical Laboratory Analysis, 1990
- Cross-reactivity of monoclonal antibodies directed against lymphocyte markers with trophoblast cells of normal placenta, hydatidiform mole, and gestational choriocarcinomaGynecologic Oncology, 1988
- ALTERATIONS IN T LYMPHOCYTE SUBPOPULATIONS ASSOCIATED WITH RENAL ALLOGRAFT REJECTIONTransplantation, 1984